elecTrIcal InSTallaTIon
Light
300 Watt
To Outlet
Max
Optional Blower
300 Watt
Max
A/C Module
noTe: Wall switch wires must
be connected together if a wall
switch is not being used.
Figure 31 -

Signature Command Wiring Diagram

electrical connections should only be
performed by a qualified, licensed electrician.
Main power supply must be turned off before
connecting fans to the main electrical power
supply or performing service.
73D4125
A/C Module
Rear Burner Solenoid
300 Watt Max
Control Board
Conversion
NG/LP
Plug-in Connector
Stepper Motor to
Control Board
Ground
DC Power/Green
Plug-in Connector
Control Board to
Solenoid
Gas In
FP2704
SCS wiring diagram
RF Receiver
ON/OFF Button
Black / Thermopile
Red / Thermopile
Sensor
Ignitor / Sparker
Plug-in Connector
Control Board to Command Center
LED
OFF/LO
Command Center
Gas Out
Pilot Gas Tubing
Valve
KSTDV Series Gas Fireplace
Pilot
ON/HI
Master Switch
Optional
Wall Switch