Figure 15. Degraded Raid 5 Array Drive When Not In Use - 3Ware Escalade 7000 Series Installation Manual

Ibm ata raid controller installation guide
Hide thumbs Also See for Escalade 7000 Series:
Table of Contents

Advertisement

3ware Escalade ATA RAID Controller Installation Guide
that is distributed on all drives. If one of the drives is removed,
unplugged or fails on read or write requests, the array is marked as
DEGRADED and the drive is marked as Not In Use or is not dis-
played if no longer available (see Figure 15). When running in
Degraded mode, the missing data is reconstructed from all non-
degraded drives.
3 w a r e D i s k A r r a y C o n f i g u r a t i o n
Available Drives:
Port 0 - QUANTUM FIREBALLP KX27.3
Disk Arrays:
Array Unit 1 - 3 drive
64K RAID 5
Port 1 - IBM-DTLA-387815
Port 2 - IBM-DTLA-387815
Port 3 - IBM-DTLA-387815
Create Array
Delete Array
Toggle Hot Spare
Alt-F1
Help
Previous/Next
$
F6
Restore Initial Values
Esc
Cancel

Figure 15. Degraded RAID 5 Array Drive When Not in Use

As in the case of RAID 1 and 10 arrays RAID 5 arrays allow you to
read and write data from a degraded disk array, but the array will
not be fault tolerant until it is rebuilt using the Rebuild feature.
(Refer to the 3ware Disk Array Configuration Utility or 3DM Disk
Management Utility chapters for more information.)
Rebuilding a mirrored or RAID 5 array with no hot spare
1 Reboot the system and enter the Disk Array Configuration
Utility.
40
512 M
1.0GB
DEGRADED
512 M
512 M
Not in Use
512 M
Maintain Array
Rebuild Array
Enter
Select/Deselect
F8
Done
www.3ware.com
2 If your mirrored or RAID 5 array has a Not in Use member
drive, the drive may still be usable. Try rebuilding with the Not
in Use drive intact. Simply select the array and then the Rebuild
button.
3 Confirm that you selected the correct array by hitting OK in the
Rebuild confirmation display.
4 Select F8 to exit the Disk Array Configuration Utility. The
array will begin rebuilding after completion of the operating sys-
tem load.
5 If the rebuild fails and you have no Available Drives, you must
power down the system and replace the failed or Not In Use
drive. Power on the system and enter the Disk Array Configu-
ration Utility.
6 Select an available drive to replace the faulted drive in the array
by navigating the cursor over the available drive and hitting
Enter (see Figure 16). An asterisk in the left most column indi-
cates the drive is selected.
7 Navigate to the degraded array and press Enter to select it.