How To Maintain Or Verify A Disk Array; Rebuilding A Mirrored Disk Array; Figure 11. Delete Disk Array Display; Figure 12. Maintain Disk Array Display - 3Ware Escalade 7000 Series Installation Manual

Ibm ata raid controller installation guide
Hide thumbs Also See for Escalade 7000 Series:
Table of Contents

Advertisement

3ware Escalade ATA RAID Controller Installation Guide
3 w a r e D i s k A r r a y C o n f i g u r a t i o n
Available Drives:
Disk Arrays:
*Array Unit 0 - 4 drive 64K RAID 0
Port 0 - QUANTUM FIREBALLP LM30
Port 1 - QUANTUM FIREBALLP LM30
Port 2 - QUANTUM FIREBALLP LM30
Port 3 - QUANTUM FIREBALLP LM30
Create Array
Delete Array
Toggle Hot Spare
Alt-F1
Help
Previous/Next
$
F6
Restore Initial Values
Esc
Cancel

Figure 11. Delete Disk Array Display

Navigate to the Delete Array button and hit Enter to bring up the
Delete Disk Array display. Check that the correct drives are listed.
Select the OK key to confirm deleting the array or Cancel to reject
it. Recall that the array is not actually deleted and no data will be
overwritten until you have finished making all your changes and
selected the F8 key.

How to maintain or verify a disk array

The Maintain Disk Array (see Figure 12) shows the current disk
array configuration that you have selected. The array's Write
Cache State can be changed. Refer to Select write cache proper-
ties paragraph in the Creating a disk array section. Verify Array
can be specified as no or yes. The default is no. Yes launches a fore-
ground process that checks the data integrity of a fault tolerant
36
120.0GB
30.0GB
30.0GB
30.0GB
30.0GB
Maintain Array
Rebuild Array
Enter
Select/Deselect
F8
Done
www.3ware.com
array. If the verify array process determines that the mirrored drives
are not identical or the parity is not correct, the array is degraded
and the rebuild process is launched.
M a i n t a i n D i s k A r r a y
The array listed below can have its write cache state changed.
Verify checks the data integrity of a fault tolerant array.
Array Unit 2 - 2 drive Mirror
Port 2
- QUANTUM FIREBALLP LM30
Port 3
- QUANTUM FIREBALLP LM30
Array's Write Cache State:
enabled
Verify Array:
no
OK
Alt-F1
Help
Previous/Next
Enter

Figure 12. Maintain Disk Array Display

Note:
Fault tolerant arrays can not be verified until
after they are initialized. For RAID 1 and 10 arrays the
initial verify must first be done in 3DM, otherwise the
initialization will not be done.

Rebuilding a mirrored disk array

Escalade ATA RAID Controllers allow you to create fault tolerant
disk arrays by selecting a mirrored RAID 1 or RAID 10 array.
These disk arrays store identical data on two or more drives to pro-
tect against drive failure. If one or more of the drives of a mirrored
www.3ware.com
3ware Disk Array Configuration Utility
30.0GB
30.0GB
30.0GB
Cancel
Change Value
Esc
Cancel
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents