OPERATING INSTRUCTIONS
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo
ignitor does not light the pilot, refer to instructions for "Match Lighting Instructions," page 29.
4. Turn gas control knob clockwise
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!
Follow "What to Do if You Smell Gas," page 27. If you don't smell gas, go to next step.
6. From OFF position, turn the gas control knob counterclockwise
control knob for 5 seconds. NOTE: If you are running the heater for the first time, it will be
necessary to press in the control knob for 30 seconds to allow air to bleed out of the gas
piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 60 seconds to prevent the flame detector from shutting
off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to ON
position or adjust thermostat to desired setting.
11. If the gas logs will not operate, follow the instructions "To Turn Off Gas To Heater" below and call your
service technician or gas supplier.
Figure 31 - Pilot
1. Turn control knob clockwise
2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.
8
MILLI-VOLT CONTROL
LIGHTING INSTRUCTIONS
to the OFF position, and turn ON/OFF switch to OFF position.
Hi/Lo Control
Ignitor Pilot Control
TO TURN OFF GAS TO HEATER
to OFF position to completely shut off the heater.
to the ON position.
Piezo
Figure 32 - Control Cover Plate for Milli-Volt
to IGN position. Push in
On/Off Switch
71D0533