Error messages

Symptom or error
Device address conflict.
Allocation error for device.
Failing bits: nnnn.
Invalid system configuration
data.
I/O device IRQ conflict.
Operating system not found.
Hibernation error.
Fan error.
Thermal sensing error.
Authentication of system
services failed. Press <Esc> to
resume.
ThinkPad R50/R50p and R51 Series
Symptom-to-FRU index
FRU or action, in sequence
1. Load "Setup Defaults" in
IBM BIOS Setup Utility.
2. Backup battery.
3. System board.
1. Load "Setup Defaults" in
IBM BIOS Setup Utility.
2. Backup battery.
3. System board.
1. DIMM.
2. System board.
1. DIMM.
2. System board.
1. Load "Setup Defaults" in
IBM BIOS Setup Utility.
2. Backup battery.
3. System board.
1. Check that the operating
system has no failure and is
installed correctly.
2. Enter IBM BIOS Setup
Utility and see whether
the hard disk drive and
the diskette drive are
properly identified.
3. Reseat the hard disk drive.
4. Reinstall the operating
system.
5. Diskette drive.
6. Hard disk drive.
7. System board.
1. Restore the system
configuration to what it
was before the computer
entered hibernation mode.
2. If memory size has been
changed, re-create the
hibernation file.
Fan.
System board.
The IBM Predesktop Area in
the HDD is corrupted.
Restore it from a recovery
CD.
59