Applications - Carrier AQUAFORCE 30XA080-500 Controls, Start-Up, Operation, Service And Troubleshooting Instructions

Air-cooled liquid chillers
Hide thumbs Also See for AQUAFORCE 30XA080-500:
Table of Contents

Advertisement

Cooler Leaving Water Temperature*
Cooler Entering Water Temperature†
30XA
Nominal Flow Rate
UNIT SIZE
(gpm)
80
180.4
82
172.8
90
201.9
92
193.7
100
225.5
102
214.3
110
244.9
112
235.2
120
264.8
122
254.7
140
317.8
142
303.5
160
365.1
162
347
180
409.6
182
401.7
200
463.9
202
447.1
220
505.9
222
493
240
545.8
242
530
260
600.3
262
583
280
642.2
282
627
300
687.5
302
665
325
733.4
327
720
350
775.4
352
757
400
917.6
450
1019.3
500
1092.8
LEGEND
DX
— Direct Expansion
*For applications requiring cooler leaving water temperature operation at less than
40 F (4.4 C), the units require the use of antifreeze and application may require
the brine option. Contact your local Carrier representative for more information.
†For applications requiring cooler entering water temperature operation at less
than 45 F (7.2 C), contact your local Carrier representative for unit selection using
the Carrier electronic catalog.
Table 44 — 30XA Minimum and Maximum Cooler Flow Rates
ITEM
Cooler
(L/s)
Standard, Flooded
11.4
Plus One Pass, Flooded
Minus One Pass, Flooded
10.9
DX Cooler
Standard, Flooded
12.7
Plus One Pass, Flooded
Minus One Pass, Flooded
12.2
DX Cooler
Standard, Flooded
14.2
Plus One Pass, Flooded
Minus One Pass, Flooded
13.5
DX Cooler
Standard, Flooded
15.5
Plus One Pass, Flooded
Minus One Pass, Flooded
14.8
DX Cooler
Standard, Flooded
16.7
Plus One Pass, Flooded
Minus One Pass, Flooded
16.0
DX Cooler
Standard, Flooded
20.1
Plus One Pass, Flooded
Minus One Pass, Flooded
19.1
DX Cooler
Standard, Flooded
23
Plus One Pass, Flooded
Minus One Pass, Flooded
21.9
DX Cooler
Standard, Flooded
25.8
Plus One Pass, Flooded
Minus One Pass, Flooded
25.3
DX Cooler
Standard, Flooded
29.3
Plus One Pass, Flooded
Minus One Pass, Flooded
28.2
DX Cooler
Standard, Flooded
31.9
Plus One Pass, Flooded
Minus One Pass, Flooded
31.1
DX Cooler
Standard, Flooded
34.4
Plus One Pass, Flooded
Minus One Pass, Flooded
33.5
DX Cooler
Standard, Flooded
37.9
Plus One Pass, Flooded
Minus One Pass, Flooded
36.8
DX Cooler
Standard, Flooded
40.5
Plus One Pass, Flooded
Minus One Pass, Flooded
39.5
DX Cooler
Standard, Flooded
43.4
Plus One Pass, Flooded
Minus One Pass, Flooded
42.0
DX Cooler
Standard, Flooded
46.3
Plus One Pass, Flooded
Minus One Pass, Flooded
45.4
DX Cooler
Standard, Flooded
48.9
Plus One Pass, Flooded
Minus One Pass, Flooded
47.8
DX Cooler
Standard, Flooded
57.9
Plus One Pass, Flooded
Minus One Pass, Flooded
Standard, Flooded
64.3
Plus One Pass, Flooded
Minus One Pass, Flooded
Standard, Flooded
68.9
Plus One Pass, Flooded
Minus One Pass, Flooded
MINIMUM
40 F (4.4 C)
45 F (7.2 C)
Number of
Minimum Flow Rate
Passes
(gpm)
2
95
3
43
1
196
86
2
101
3
43
1
229
97
2
101
3
43
1
229
107
2
125
3
61
1
254
118
2
125
3
73
1
281
127
2
134
3
73
1
324
152
2
165
3
98
1
354
174
2
202
3
73
1
416
201
2
223
3
98
1
458
224
2
235
3
122
1
501
246
2
266
3
147
1
538
265
2
257
3
141
1
584
292
2
293
3
141
1
620
313
2
327
3
174
1
687
333
2
361
3
211
1
724
360
2
379
3
244
1
767
379
1
501
1
501
1
501
NOTES:
1. The 30XA units will start and pull down with loop temperatures up to 95 F (35 C).
2. Nominal flow rates required at AHRI conditions 44 F (7 C) leaving fluid tempera-
ture, 54 F (12 C) entering water temperature, 95 F (35 C) ambient. Fouling factor
0.00010 ft
2
-hr-F/Btu (0.000018 m
3. To obtain proper temperature control, cooler loop fluid volume must be at least
3 gal/ton (3.23 L/kW) of chiller nominal capacity for air conditioning and at least
6 gal/ton (6.5 L/kW) for process applications or systems that must operate in low
ambient temperatures (below 32 F [0° C]).
61
MAXIMUM
60 F (15 C)
70 F (21.1 C)
Maximum Flow Rate
(L/s)
(gpm)
(L/s)
6
379
23.9
2.7
192
12.1
12.4
782
49.3
5.4
346
21.8
6.4
403
25.4
2.7
200
12.6
14.4
917
57.9
6.1
387
24.4
6.4
403
25.4
2.7
200
12.6
14.4
917
57.9
6.7
429
27.0
7.9
501
31.6
3.8
244
15.4
16
1014
64
7.4
470
29.6
7.9
501
31.6
4.6
293
18.5
17.7
1124
70.9
8.0
509
32.1
8.5
538
33.9
4.6
293
18.5
20.4
1296
81.8
9.6
607
38.2
10.4
660
41.6
6.2
391
24.7
22.3
1418
89.5
10.9
694
43.7
12.7
807
50.9
4.6
391
24.7
26.2
1662
104.9
12.6
803
50.6
14.1
892
56.3
6.2
391
24.7
28.9
1833
115.6
14.1
894
56.3
14.8
941
59.4
7.7
489
30.9
31.6
2004
126.4
15.5
950
59.9
16.8
1063
67.1
9.3
587
37
33.9
2151
135.7
16.7
950
59.9
16.2
1027
64.8
8.9
562
35.5
36.8
2334
147.3
18.4
950
59.9
18.5
1173
74
8.9
562
35.5
39.1
2481
156.5
19.8
950
59.9
20.6
1308
82.5
11
697
44
43.3
2750
173.5
21.0
1331
83.9
22.8
1442
91
13.3
843
53.2
45.7
2897
182.8
22.7
1440
90.8
23.9
1516
95.6
15.4
978
61.7
48.4
3068
193.6
23.9
1514
95.5
31.6
2004
126.4
31.6
2004
126.4
31.6
2004
126.4
2
-K/kW).