Central Heating Function; Ignition Sequence - Worcester GREENSTAR 24i junior Instruction Manual

Wall hung rsf gas fired condensing combination boiler for sealed central heating systems and mains fed domestic hot water
Table of Contents

Advertisement

Room
thermostat and/or
mains
programmer ON
(or link fitted at
ST10)
POWER
BLUE
AND
SWITCH
LIGHT
Facia mounted
ON
ON
programmer (if fit-
ted) ON
AND
CH control knob
ON
FAULT FINDING
& DIAGRAMS
3 minute wait
Fan to
IGNITION
CENTRAL
start
SEQUENCE
HEATING
DEMAND
speed.
(see detail)
Diverter valve
in CH position

IGNITION SEQUENCE

Pump ON.
Spark
ignition
4 seconds
NO
YES
5th
LOCKOUT
attempt?
Over temperature shut-
Gas valve OFF.
down if water tempera-
Fan overrun
ture is 5°C above set
30 seconds
Fan (& gas)
GREEN
10 second
FLAME
stabilisation
LIGHT
period.
temperature
ON
YES
BURNER
LIT?
NO
Stop spark.
Wait
10 seconds
value.
modulation
END OF
to achieve
BOILER
set
DEMAND
(40-82°C)
Gas valve
OFF
Pump run 3
minutes
Fan run 30
seconds