Worcester GREENSTAR 24i junior Instruction Manual page 28

Wall hung rsf gas fired condensing combination boiler for sealed central heating systems and mains fed domestic hot water
Table of Contents

Advertisement

Apply silicone
grease to seal
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior
8 716 115 166a (06/2008)
This screw should
be fitted last for
easier installation
Flat at back
FLUE INSTALLATION
4 Assemble elbow to boiler using the three
screws (see below).
Note: Screws are in boiler not in flue kit.
FITTING THE ELBOW:
Flue elbow should push directly down and
not be twisted into correct position.
Remove the 3 inner flue tube retaining
screws. The inner tube will be held in place
in the appliance.
Fit turret onto appliance and retain with the
three removed screws.
NOTE: The clamping plate flat should be at
the rear of the appliance.
ADDITIONAL NOTES AND REMINDERS:
• Ensure that all cut lengths are square and
free from burrs.
• The flue, when assembled, is fully sealed and
components are pushed home.
• The flue is set at an angle of 3° or 52mm per
1m length.
This screw should
be fitted last for
rear exit
27
FLUE INSTALLATION

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 28i junior

Table of Contents