Note for Multi System
■ OUTDOOR UNIT QUIET operation
1. With the priority room setting present but inactive or not present.
When using the OUTDOOR UNIT QUIET operation feature with the Multi system, set all indoor
units to OUTDOOR UNIT QUIET operation using their remote controllers.
When clearing OUTDOOR UNIT QUIET operation, clear one of the operating indoor units using their remote controller.
However OUTDOOR UNIT QUIET operation display remains on the remote controller for other rooms.
We recommend you release all rooms using their remote controllers.
2. With the priority room setting active.
See "Priority room setting".
■ COOL/HEAT mode lock
(Available only for heat pump models)
The COOL/HEAT mode lock requires initial programming during installation. Please consult your authorized dealer
for assistance. The COOL/HEAT mode lock sets the unit forcibly to either COOL or HEAT operation. This function
is convenient when you wish to set all indoor units connected to the multi system to the same operation mode.
NOTE
• The COOL/HEAT mode lock cannot be activated together with the priority room setting.
■ Priority room setting
The priority room setting requires initial programming during installation. Please consult your retailer or dealer for assistance.
The room designated as the priority room takes priority in the following situations;
1. Operation mode priority.
As the operation mode of the priority room takes precedence, the user can select a different operation mode from other rooms.
* Room A is the priority room in the examples.
〈Example〉
When COOL operation is selected in room A while operating the following modes in room B, C and D:
Operation mode in
room B, C and D
COOL or DRY or FAN
2. Priority when POWERFUL operation is used.
* Room A is the priority room in the examples.
〈Example〉
The indoor units in rooms A, B, C and D are all operating. If the unit in room A enters
POWERFUL operation, operation capacity will be concentrated in room A. In such a case, the
cooling (heating) efficiency of the units in rooms B, C and D may be slightly reduced.
3. Priority when using OUTDOOR UNIT QUIET operation.
* Room A is the priority room in the examples.
〈Example〉
Just by setting the unit in room A to QUIET operation, the air conditioner starts OUTDOOR UNIT QUIET operation.
You don't have to set all the operated indoor units to QUIET operation.
32
Current operation mode maintained
The unit enters standby mode. Operation resumes when
HEAT
the room A unit stops operating.
If the unit is set to COOL operation, it continues. If set to
AUTO
HEAT operation, it enters standby mode. Operation
resumes when the room A unit stops operating.
(page 19.)
Status of room B, C and D when the unit
in room A is in COOL operation