NOTE
■ Note on combination of COMFORT AIRFLOW operation and INTELLIGENT EYE
operation
• The airflow rate will be set to AUTO. If the upper and lower airflow direction is selected, the
COMFORT AIRFLOW operation will be canceled.
Priority is given to the function of whichever button is pressed last.
• The air conditioner can go into operation with the COMFORT AIRFLOW and INTELLIGENT
EYE functions combined.
The flaps adjust the airflow direction upward (while in cooling operation) and downward
(while in heating operation), during which the sensors of the INTELLIGENT EYE are working
to detect the movement of people. When the sensors detect people, the louvers will direct
the airflow in such way that it will not be blown directly on them. If there are no people, the air
conditioner will go into energy-saving operation after 20 minutes.
INTELLIGENT EYE operation is useful for energy saving
■ Energy saving operation
• If no presence detected in the room for 20 minutes, the energy saving operation will start.
• This operation changes the temperature –2°C in HEAT / +2°C in COOL / +2°C in DRY
operation from set temperature.
• This operation decreases the airflow rate slightly in FAN operation only.
CAUTION
• Do not place large objects near the sensor.
Also keep heating units or humidifiers outside the sensor's detection area. This sensor can
detect undesirable objects.
• Do not hit or violently push the INTELLIGENT EYE sensor. This can lead to damage and
malfunction.
17