AMX Modero NXD/NXT-1200VG Operation/Reference Manual page 65

Vg series modero touch panels
Table of Contents

Advertisement

Install the four #4-40
screws into the places
A - Faceplate
(bezel)
FIG. 39
Wall Mount panel installation configuration for pre-existing conduit/wallbox in a pre-wall construction
2.
Verify the incoming RJ-45, Ethernet, USB, and any other audio/video cables have been properly threaded
through the wiring knockouts (from their terminal locations) on the conduit box. Leave enough slack in
the wiring to accommodate any re-positioning of the panel.
3.
Connect all data and power wiring connectors to their corresponding locations along the side of the (un-
powered) NXD touch panel.


4.
Test the incoming wiring by connecting the panel connections to their terminal locations and applying
power. Verify the panel is receiving power and functioning properly to prevent repetition of the
installation.
5.
Disconnect the terminal end of the power cable from the connected power supply.
Don't disconnect the connectors from the touch panel. The unit must be installed with
the attached connectors before being inserted into the conduit box.
6.
Carefully slide the main unit (B in FIG. 39) into the conduit box, so that all Mounting Tabs lie flush
against the conduit box (C in FIG. 39).
7.
Insert and secure the four securing #4-40 Mounting Screws into their corresponding holes located along
the sides of the NXD (FIG. 38 and FIG. 39).
8.
Place the magnetic faceplate (A in FIG. 39) back onto the main NXD unit (B in FIG. 39). Make sure to
align the Microphone, Light, and PIR Motion sensor locations to their respective openings on the front
bezel/faceplate.
VG-Series Modero Touch Panels
Stud
Cable
knockouts
Mounting Tab
indicated
Verify the terminal end of the power cable is not connected to a power supply before plugging in the
2-pin power connector.
The USB connectors can be from either a USB extension cable, or a wireless USB RF transmitter.
Installation Procedures: 12" and 15" Panels
SURFACE
Do not use these
tabs to mount
the conduit /wallbox
These are ONLY used to
secure the main unit to the CB
B - Main NXD unit consists of
the touch panel and backbox housing
C - Optional CB-TP
conduit/wallbox
Installed flush
against the
finished wall
surface
51