Security Settings; Security Profile Features - AMX Modero NXD/NXT-1200VG Operation/Reference Manual

Vg series modero touch panels
Table of Contents

Advertisement

Protected Setup Page Elements (Cont.)
System Recovery:
Channel Port
Level Port
Channel Code
Number
FIG. 118
Button/slider Function Show example

Security Settings

The Security button on the Protected Setup page has three settings: Standard Security, Secure, and
DoD. Each setting has different features for touch panel security:

Security Profile Features

Standard Security: • Factory default, shipped in this configuration.
Secure:
VG-Series Modero Touch Panels
Allows you to either reset the touch panel to factory default settings and/or wipe
out all existing touch panel pages:
• The Reset System Settings button allows a user to wipe out all current
configuration parameters on the touch panel (such as IP Addresses, Device
Number assignments, Passwords, and other presets).
- Pressing this button launches a Confirmation dialog that asks you to confirm
your selection.
- This dialog is configured with a delay timer that does not enable the YES
button for 5 seconds. This delay provides an additional amount of time for
the user to confirm their decision.
• The Remove User Pages button allows you remove all current TPD4 touch
panel pages currently on the panel (including the pre-installed AMX Demo
pages).
- Pressing this button launches a Confirmation dialog which asks you to
confirm your selection.
- This dialog is configured with a delay timer that does not enable the YES
button for 5 seconds. This delay provides an additional amount of time for
the user to confirm their decision.
Channel Code
Number
3,132
Address
Port
Button
2,8
3,50
Address Code
Number
• Administrator and NetLinx user accounts have a default password of "password".
• Telnet, HTTP, HTTPS, and SSH are all enabled and require no authentication.
• Program terminal requires no authentication.
• ICSP communication protocol between devices: encryption and authentication are
disabled.
• FTP is enabled.
• Minimum password requirement is 4 characters.
• Must be configured from the program terminal.
• HTTP, Telnet, and FTP are disabled.
• SSH, HTTPS, and program terminal require authentication by an authorized user.
• SSH, HTTPS, and program terminal session timeouts are enabled.
• ICSP communication protocol between devices: encryption and authentication are
enabled.
• Minimum password requirement is 8 characters with at least 1 numeric character.
• Login failure attempt pauses 4 seconds before another login attempt is allowed.
• After 3 consecutive unsuccessful login attempts, login lockout is enabled for 15
minutes.
• Login and logout audit logging is enabled.
Firmware Pages and Descriptions
Channel Port
7,10
Slider
Level Port
4,9
1,8
Channel Code
Number
Channel Code
Number
Address
Port
Address Code
Number
145

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents