Installation; Step 2: Check Installation Hardware; Step 3: Ductwork, Wiring, Hood Attachment Locations - GE Monogram ZV750 Installation Instructions Manual

36" vent hood
Hide thumbs Also See for Monogram ZV750:
Table of Contents

Advertisement

2
Locate the hardware accessory box packed
with range hood and check contents.
Step
Check

Installation

Hardware
Utility Bars with Screws
3
To determine ductwork locations:
• Locate the template packed with the
S tep
literature.
• Determine the exact installation location.
– Measure 36" from the floor to the top
Ductwork,
Wiring,
Hood
Attachment
– Use a level to draw a straight pencil line
Locations
– Tape the template in position along the
• Measure from the peak of the hood
to the ceiling as indicated. The dimension
should be:
– 26-1/4" to 38-1/4" for 8 ft. to 9 ft. ceilings.
– 38-1/4" to 50-1/4" for 9 ft. to 10 ft.
CEILING DUCTING
If ductwork will vent straight up to the ceiling:
• Use a level to draw a line straight up, from
the centerline on the template to the ceiling.
• Measure 3-1/2" from the back wall to the
centerline of a 6-1/2" dia. hole on the
ceiling.
Note: If drywall is not present, add drywall thickness to the
3-1/2" dimension.
Duct Cover Bracket
2 Phillips Head Screws
of the cooking surface. Add 25-1/2"
recommended space from the cooking
surface to bottom of hood. Mark that
location.
on the wall.
penciled line. CHECK TO BE SURE
TEMPLATE IS LEVEL.
ceilings (This installation requires
ZX10SY accessory duct cover.)
Installation
10
Wall
Fasteners
2 Mounting
Brackets
3 Filters
6-1/2" Dia. Hole
FOR WALL VENT DUCT
WALL DUCTING
If ductwork will vent to the rear:
• Use the level to draw a line straight up from
the centerline on the template.
• Measure at least 6" above the bracket location
shown on the template to the centerline of
the 6-1/2" dia. duct hole. (Hole may need to
be elongated for duct elbow.)
HOUSE WIRING LOCATION:
• The junction box is located on the top of the
hood, at the front right side.
• Route house wiring as close to the installation
location as possible, through the ceiling, soffit
or back wall. Wiring should enter at least 4"
above the bracket on the right side.
36" Vent Hood
2 Large
Flat Washers
10
Wood
Screws
• Drill 1/8" Pilot Holes For Mounting Brackets.
• Drill 1/8" Pilot Holes.
Align edge 25-1/2" above Cooking Surface.
Wall Mount Template
FOR CEILING
3 1/2"
VENT DUCTING
Centerline To Wall
Centerline
6" Min. Above
Bracket Location
• Drill 1/8" Pilot Holes For Mounting Brackets.
5-7/8"
17-5/16"
C L
• Drill 1/8" Pilot Holes.
Align edge 25-1/2" above Cooking Surface.
Decorative
Duct
Cover
C L
5-7/8"
26-14" to 8 ft. Ceiling
38-1/4" to 9 ft. Ceiling
38-1/4" to 50-1/4" For
9ft. to 10 ft. Ceiling
Using Optional Accessory
ZX10SY Duct Cover
C L
17-5/16"
C L
• Drill 1/8" Pilot Holes.
26-14" to 8 ft. Ceiling
38-1/4" to 9 ft. Ceiling
38-1/4" to 50-1/4" For
9ft. to 10 ft. Ceiling
Using Optional Accessory
ZX10SY Duct Cover
• Drill 1/8" Pilot Holes.