Programming; Manual Operation; Setting Time And Day; Programmable Thermostats - Bryant LEGACY LINE-RNC T1-PAC Installation Instructions Manual

Legacy line-rnc series programmable thermostats
Table of Contents

Advertisement

T1- -PAC
T1- -PHP
LEGACY LINE- - RNC

PROGRAMMABLE THERMOSTATS

Legacy Line- -RNC Series Programmable Thermostat

SETTING TIME AND DAY

At Power Up
When power is first applied, AC or HP will appear for 5 seconds to
tell you it is an air conditioner (AC) or a heat pump (HP) model.
After this, the time display will flash to tell you the power has been
off.
Setting The Current Time:
1. Press the TIME/TEMP button. SET TIME flashes on the
display.
2. Press the UP or DOWN button until the correct time is
displayed.
3. To quickly advance to the proper time, press and hold the
UP or DOWN button.
4. When the correct time appears on the display, press the
HOLD/END button.
NOTE: If you choose not to press the HOLD/END button, the
thermostat will automatically exit the time setting mode after 10
seconds.
Setting The Current Day:
1. Press the DAY button to advance to the correct day.
2. When the correct day appears on the display, press the
HOLD/END button.

MANUAL OPERATION

To Operate Manually (Without the Programmed
Comfort Schedule):
Press the HOLD/END button to make the HOLD icon appear.
Then follow the four steps below:
Homeowner's Guide
A07109
1. To Select the Mode:
Use the H/C button to move between the choices. OFF,
HEAT, COOL, or EMHT will appear on the display. EMHT
will only appear on heat pump models.
2. To Select the Fan Operation:
Use the FAN button to move between continuous fan
(indicated by the FAN ON icon) and auto fan operation.
3. To Read the Room Temperature:
The large display reads room temperature until a button is
pressed.
4. To Adjust the Setpoint:
In normal operation, the large display shows room
temperature. At the first press of the UP or DOWN button,
the large display shows the current setpoint and the SET
TEMP icon is turned on. Further presses of the UP or
DOWN button adjust the setpoint upward or downward.
Five seconds after the last button press, the display returns
to the room temperature and the SET TEMP icon turns off.
PROGRAMMED OPERATION
Introduction
The Legacy Line- -RNC Series Programmable Thermostat provides
four periods per day (MORNING, DAY, EVE, NIGHT) and two
schedules per week (MoTuWeThFr and SaSu). A separate time,
heat setpoint, and cool setpoint can be set for each period and
schedule. Before starting to actually program the thermostat, fill
out Table 1 with the values you wish to program. (The Energy
Starr, US Department of Energy recommended time and
temperature values are already programmed for you as a starting
point and are shown on the left side of the table.)
The first press of the PROGRAM button brings up the
programming mode and places you at morning of the current day
and period. Successive presses move you between the four daily
periods.
While Programming:
The TIME/TEMP button moves between three selections of SET
TIME, SET TEMP & HEAT, and SET TEMP & COOL. These
three numbers are to be programmed for each of the periods
MORNING, DAY, EVE, and NIGHT.
The DAY button moves between the weekdays, (MoTuWeThFr)
and the weekend (SaSu) selections. A different schedule may be set
for the weekdays and the weekend. You may exit programming at
any time by pressing the HOLD/END button.
Programming A Weekly Comfort Schedule:
1. Press the PROGRAM button. The word PROGRAMMING
appears on the display and the words SET TIME flash on
the display. MoTuWeThFr or SaSu and the morning period
icons will appear on the display. The current mode (HEAT
or COOL) will also show. Use the DAY button to select
weekdays and the PROGRAM button to select MORNING.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Legacy line-rnc t1-php

Table of Contents