Check the appliance is electrically safe and gas sound when you have nished.

Conversion to Another Gas

If the appliance is to be converted to another gas do the
conversion at this point. See the conversion section of these
instructions and see the instructions in the conversion kit.

Levelling

You are recommended to use a spirit level on a shelf in one of
the ovens to check for level.
Place the cooker in its intended position, taking care not to
twist it within the gap between the kitchen units as damage
may occur to the cooker or the units.
The front feet and rear rollers can be adjusted to level the
cooker.
To adjust the height of the rear of the cooker use a 13 mm
spanner or socket wrench to turn the adjusting nuts at the
front bottom corners of the cooker.
To set the front, turn the feet bases to raise or lower.

Gas Connection

This must be in accordance with the relevant standards.
The exible hose (not supplied with the cooker) must be
in accordance with the relevant standards. Hoses may be
purchased at most builders' merchants.
We recommend that a Micropoint gas hose is used when
installing this appliance.
The gas supply needs to terminate with a side-facing elbow
with a down-facing bayonet.
The connector is located just below the hotplate level at the
rear of the cooker. If in doubt contact your supplier.
The rear cover boxes limit the position of the supply point.
Because the height of the cooker can be adjusted and
each connection is di erent, it is di cult to give precise
dimensions.
Although a 900 mm hose can be used, a 1100 mm hose
will allow slightly more exibility in the positioning of the
bayonet and make moving the cooker easier.
The hose should be tted so that both inlet and outlet
connections are vertical so that the hose hangs downwards in
a 'U' shape.
Ideally the hose supply connection should be within the
shaded area 'A' (Fig.7-10).
For Natural Gas, the exible hose must be in accordance with
BS 669. For LP Gas, it should be capable of 50 mbar pressure,
70 °C temperature rise, and carry a red stripe, band or label. If
in doubt contact, your supplier.
Screw connect the threaded end of the hose into the gas
inlet. After completing the gas connection, make sure that
the cooker is gas sound with a pressure test.
INSTALLATION
Wall
Gas inlet
680
450
All dimensions in millimetres
23
Outer stability
bracket
3 mm min
Typical wall mounting
750
500
Fig.7-9
Cooker
Floor
Fig.7-10
A