Gas Piping - Carrier 58CTA Installation, Start-Up, Operating And Service And Maintenance Instructions

2-stage deluxe, induced combustion 4-way multipoise gas furnace series 140/e
Table of Contents

Advertisement

FURNACE
RETURN---AIR
SIZE
INLET
Bottom
135--- 16/
or
048135
Side(s)
Bottom
Only
Bottom Sides
135--- 22/
or
066135
1 Side & Bottom
1 Side Only
Bottom Only
155--- 20/
060155
Both Sides Or 1
Side & Bottom
1 Side Only
*A filter is required for each return ---air inlet. Airflow performance included 3/4 ---in. (19 mm) washable filter media such as contained in factory ---authorized ac-
cessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 In. W.C. available external static pressure.
--- --- Indicates unstable operating conditions.
Downflow Furnaces
Connect supply- -air duct to supply- -air outlet on furnace. Bend
flange inward past 90_ with wide duct pliers. (See Fig. 14.) The
supply- -air duct must be connected to ONLY the furnace
supplyoutlet or air conditioning coil casing (when used). When
installed on combustible material, supply- -air duct must be
connected to ONLY the factory- -approved accessory subbase, or
a factory approved air conditioning coil casing. DO NOT cut
main furnace casing to attach supply side air duct, humidifier, or
other accessories. All accessories MUST be connected to duct
external to furnace casing.
Return Air Connections
WARNING
!
FIRE HAZARD
Failure to follow this warning could cause personal injury,
death and/or property damage.
Never connect return- -air ducts to the back of the furnace.
Follow instructions below.
Downflow Furnaces
The return- -air duct must be connected to return- -air opening
(bottom inlet) as shown in Fig. 1. DO NOT cut into casing sides
(left or right). Side opening is permitted for only upflow and most
horizontal furnaces. Bypass humidifier connections should be
made at ductwork or coil casing sides exterior to furnace. (See
Fig. 19.)
Upflow and Horizontal Furnaces
The return- -air duct must be connected to bottom, sides (left or
right), or a combination of bottom and side(s) of main furnace
casing as shown in Fig. 1. Bypass humidifier may be attached
into unused return air side of the furnace casing. (See Fig. 18 and
20.) Not all horizontal furnaces are approved for side return air
connections. (See Fig. 20.)
Table 5 - - Air Delivery - - CFM (With Filter)* (Cont.)
SPEED
0.1
0.2
High
2090
2010
Med --- High
1790
1755
Med --- Low
1545
1525
Low
1325
1320
High
2485
2400
Med --- High
2195
2150
Med --- Low
1880
1850
Low
1640
1635
High
--- ---
--- ---
Med --- High
2180
2145
Med --- Low
1880
1850
Low
1640
1635
High
2320
2250
Med --- High
2125
2065
Med --- Low
1845
1825
Low
1640
1620
High
2465
2430
Med --- High
2115
2105
Med --- Low
1800
1790
Low
1570
1565
High
--- ---
--- ---
Med --- High
2155
2135
High
--- ---
--- ---
Med --- High
2140
2095
EXTERNAL STATIC PRESSURE (IN. W.C.)
0.3
0.4
0.5
0.6
1930
1835
1710
1590
1705
1640
1550
1465
1500
1450
1380
1315
1295
1265
1210
1150
2310
2215
2110
2000
2090
2000
1920
1825
1820
1780
1715
1635
1615
1585
1530
1465
2385
2305
2195
2085
2060
2010
1945
1865
1820
1780
1715
1635
1615
1585
1530
1465
2155
2055
1970
1855
1995
1910
1815
1710
1765
1710
1650
1570
1580
1540
1485
1410
2375
2305
2230
2110
2075
2030
1980
1910
1770
1735
1695
1640
1550
1525
1495
1445
2375
2285
2200
2105
2095
2040
1975
1895
2260
2180
2085
1975
2040
1975
1890
1810

GAS PIPING

WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury, death, and/or property damage.
Never purge a gas line into a combustion chamber. Never
test for gas leaks with an open flame. Use a commercially
available soap solution made specifically for the detection
of leaks to check all connections.
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to follow this warning could result in personal
injury, death, and/or property damage.
Use proper length of pipe to avoid stress on gas control
manifold and a gas leak.
WARNING
!
FIRE OR EXPLOSION HAZARD
Failure to protect gas valve inlet from water and debris
could result in death, personal injury and/or property
damage.
Gas valve inlet and/or inlet pipe must remain capped until
gas supply line is permanently installed to protect the valve
from moisture and debris. Also, install a sediment trap in the
gas supply piping at the inlet to the gas valve.
17
0.7
0.8
0.9
1.0
1470
1335
1025
835
1360
1210
945
785
1215
1005
855
670
995
865
745
540
1880
1725
1535
1355
1720
1565
1405
1255
1540
1415
1290
1160
1370
1255
1150
1040
1960
1825
1670
1465
1765
1660
1515
1325
1540
1415
1290
1160
1370
1255
1150
1040
1725
1600
1450
1280
1610
1490
1340
1175
1475
1370
1240
1100
1330
1220
1080
960
2000
1865
1725
1545
1830
1725
1590
1425
1570
1465
1345
1225
1370
1270
1175
1070
1995
1870
1730
1570
1790
1685
1550
1400
1865
1740
1605
1455
1705
1595
1480
1325