Carrier Infinity 96 58UVB Product Data page 12

100 series 95% afue upflow only variable-speed condensing input rates 60,000 thru 120,000 btuh
Table of Contents

Advertisement

AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER)* CONTINUED
OPERATING
UNIT SIZE
MODE
100--- 20#
Low Heat
High Heat
2 ---Ton A/C
††
Cooling
2 ---1/2 ---Ton A/C
††
Cooling
3 ---Ton A/C
Cooling
3 ---1/2 ---Ton A/C
Cooling
4 ---Ton A/C
Cooling
5 ---Ton A/C
Cooling
Maximum
120--- 20
Low Heat
High Heat
2 ---Ton A/C
††
Cooling
2 ---1/2 ---Ton A/C
††
Cooling
3 ---Ton A/C
Cooling
3 ---1/2 ---Ton A/C
Cooling
4 ---Ton A/C
Cooling
5 ---Ton A/C
Cooling
6 ---Ton A/C
Cooling
Maximum
* Actual external static pressure (ESP) can be determined by using the fan laws (CFM
would operate at high ---heating airflow of 1500 CFM at 0.37 ESP and low---heating airflow of 705 CFM at 0.08 ESP .
{ Low heat CFM when low---heat rise adjustment switch (SW1 ---3) and comfort/efficiency adjustment switch (SW1 ---4) on control center are OFF.
Ductwork must be sized for high ---heating CFM within the operational range of ESP .
}
Operation within the blank areas of the chart is not recommended because high ---heat operation will be above 1.0 ESP .
{{
# All airflows for 21 in. casing size furnaces are 5% less on side return only installations.
EXTERNAL
CFM
STATIC
AIRFLOW
PRESSURE
SETTING
0.1
RANGE*
1110†
0 ---1.0
1060
1525
0 ---1.0
1525
700
0 ---0.50‡
700
875
0 ---0.50‡
865
1050
0 ---1.0‡
1035
1225
0 ---1.0‡
1180
1400
0 ---1.0‡
1400
1750
0 ---1.0
1740
2000
0 ---1.0
2000
1380†
0 ---1.0
1345
1885
0 ---1.0
1875
700
0 ---0.50‡
700
875
0 ---0.50‡
875
1050
0 ---1.0‡
1035
1225
0 ---1.0‡
1205
1400
0 ---1.0‡
1390
1750
0 ---1.0‡
1745
2100
0 ---1.0
2100
2100
0 ---1.0
2100
EXTERNAL STATIC PRESSURE (ESP)
0.2
0.3
0.4
0.5
1075
1080
1095
1110
1525
1525
1525
1520
700
700
690
685
875
870
870
875
1045
1050
1045
1050
1195
1215
1225
1225
1400
1400
1400
1400
1745
1750
1750
1750
2000
2000
2000
2000
1365
1380
1380
1380
1880
1885
1885
1885
700
700
700
695
875
875
870
870
1040
1050
1050
1050
1210
1225
1225
1225
1400
1400
1400
1400
1740
1745
1745
1745
2100
2100
2100
2100
2100
2100
2100
2100
2
proportional to ESP); such as, a system with 1750 CFM at 0.5 ESP
12
0.6
0.7
0.8
0.9
1110
1110
1110
1110
1515
1515
1515
1515
1050
1050
1050
1050
1225
1225
1225
1225
1400
1400
1395
1375
1750
1750
1750
1750
2000
1985
1965
1940
1380
1380
1375
1360
1885
1885
1885
1880
1050
1050
1025
1005
1225
1225
1225
1220
1400
1395
1385
1370
1745
1745
1740
1730
2095
2075
2040
1975
2095
2075
2040
1975
1.0
1110
1515
1045
1225
1365
1740
1910
1355
1870
1000
1215
1360
1715
1910
1910