Model number nomenclature

30XA – Air-Cooled AquaForce™ Chiller
Design Series
Unit Sizes
080 140 240 350
090 160 260 400
100 180 280 450
110 200 300 500
120 220 325
Voltage
1 – 575-3-60
2 – 380-3-60
4 – 230-3-60
6 – 460-3-60
7 – 200-3-60
Condenser Coil/High Ambient Options
6 – Aluminum Fin/Copper Tube, High Ambient Temperature,
Compressor Enclosures
8 – Aluminum Pre-Coat Fin/Copper Tube, High Ambient Temperature,
Compressor Enclosures
9 – Aluminum E-Coat Fin/Copper Tube, High Ambient Temperature,
Compressor Enclosures
F – Aluminum Fin/Copper Tube, Standard Ambient Temperature,
Compressor Enclosures
H – Aluminum Pre-Coat Fin/Copper Tube, Standard Ambient
Temperature, Compressor Enclosures
J – Aluminum E-Coated Fin/Copper Tube, Standard Ambient
Temperature, Compressor Enclosures
Not Used
Cooler/Brine Options
0 – Integral Cooler
3 – Integral Cooler, Minus One Pass
5 – Integral Cooler, Plus One Pass
B – Integral Cooler, Brine
F – Integral Cooler, Minus One Pass, Brine
H – Integral Cooler, Plus One Pass, Brine
LEGEND
EMM
Energy Management Module
GFI-CO —
Ground Fault Interrupting Convenience Outlet
LON
Local Operating Network
XL
Across-the-Line Starter
Quality Assurance
Certified to ISO 9001:2000
4
AQUAFORCE™ CHILLER MODEL NUMBER DESIGNATION
30XA
-
200
6
F
-
0
-
-
-
L
Packaging/Security Options
L – Coil Face Shipping Protection (CFSP)
0 – CFSP, Skid
1 – Skid, Top Crate, Bag
3 – CFSP, Coil Trim Panels
4 – CFSP, Skid, Coil Trim Panels, Shipping
5 – Skid, Top Crate, Bag, Coil Trim Panels
Controls/Communication Options
- – None
0 – EMM
1 – Remote Service Ports, GFI-CO
2 – EMM, Remote Service Port, GFI-CO
7 – BACnet™ Translator
8 – BACnet Translator, EMM
9 – BACnet Translator, Remote Service Port, GFI-CO
B – BACnet Translator, EMM, Remote Service Port, GFI-CO
H – LON Translator
J – LON Translator, EMM
K – LON Translator, Remote Service Port, GFI-CO
L – LON Translator, EMM, Remote Service Port, GFI-CO
Electrical Options
- – Single Point Power, XL, Terminal Block, No Control Transformer
0 – Single Point Power, Wye-Delta, Terminal Block, No Control Transformer
3 – Dual Point Power, XL, Terminal Block, No Control Transformer
4 – Dual Point Power, Wye-Delta, Terminal Block, No Control Transformer
7 – Single Point Power, XL, Disconnect, No Control Transformer
8 – Single Point Power, Wye-Delta, Disconnect, No Control Transformer
C – Dual Point Power, XL, Disconnect, No Control Transformer
D – Dual Point Power, Wye-Delta, Disconnect, No Control Transformer
H – Single Point Power, XL, Terminal Block, Control Transformer
J – Single Point Power, Wye-Delta, Terminal Block, Control Transformer
M – Dual Point Power, XL, Terminal Block, Control Transformer
N – Dual Point Power, Wye-Delta, Terminal Block, Control Transformer
R – Single Point Power, XL, Disconnect, Control Transformer
S – Single Point Power, Wye-Delta, Disconnect, Control Transformer
W – Dual Point Power, XL, Disconnect, Control Transformer
X – Dual Point Power, Wye-Delta, Disconnect, Control Transformer
Refrigeration Circuit Options
- – None
1 – Suction Service Valves
2 – Low Ambient Temperature Head Pressure Control
5 – Suction Service Valves, Low Ambient Temperature Head Pressure Control