Electrical Data - Carrier AQUAFORCE 30XA080-500 Product Data

Air-cooled liquid chillers 80 to 500 nominal tons
Table of Contents

Advertisement

Electrical data

VOLTAGE RANGE
UNIT
VOLTAGE
30XA
(3 Ph, 60 Hz)
Min
200
187
230
207
140
380
342
460
414
575
518
200
187
230
207
160
380
342
460
414
575
518
200
187
230
207
180
380
342
460
414
575
518
200
187
230
207
200
380
342
460
414
575
518
200
187
230
207
220
380
342
460
414
575
518
200
187
230
207
240
380
342
460
414
575
518
380
342
260
460
414
575
518
380
342
280
460
414
575
518
380
342
300
460
414
575
518
380
342
325
460
414
575
518
380
342
350
460
414
575
518
380
342
400
460
414
575
518
380
342
450
460
414
575
518
380
342
500
460
414
575
518
LEGEND
ICF
— Instantaneous Current Flow
MCA
— Minimum Circuit Amps
MOCP — Maximum Overcurrent Protection
WD
— Wye-Delta
XL
— Across-the-Line
NOTES:
1. The high ambient option is not available on 30XA080-120 units.
2. Units are suitable for use on electrical systems where voltage supplied to the unit terminals
is not below or above the listed minimum and maximum limits. Maximum allowable phase
imbalance is: voltage, 2%; amps 10%.
3. Cooler heater is wired into the control circuit so it is always operable as long as the contol
power supply disconnect is on, even if any safety device is open.
4. For MCA that is less than or equal to 380 amps, 3 conductors are required.
For MCA between 381-760 amps, 6 conductors are required.
For MCA between 761-1140 amps, 9 conductors are required.
For MCA between 1141-1520 amps, 12 conductors are required.
Calculation of conductors required is based on 75 C copper wire.
30XA140-500 (HIGH AMBIENT TEMPERATURE OPTION)
MAIN POWER
SUPPLY
MCA
Max
QTY REQD
220
1
618.8
253
1
561.9
418
1
327.9
506
1
282.0
633
1
216.2
220
2
477.9/273.7
253
2
434.8/249.1
418
1
374.5
506
1
321.5
633
1
247.0
220
2
422.4/422.4
253
2
383.8/383.8
418
1
410.3
506
1
353.1
633
1
271.0
220
2
477.9/477.9
253
2
434.8/434.8
418
1
463.4
506
1
398.1
633
1
305.6
220
2
567.4/477.9
253
2
516.0/434.8
418
1
511.0
506
1
439.3
633
1
337.3
220
2
567.4/555.5
253
2
516.0/505.2
418
1
543.9
506
1
467.8
633
1
359.2
418
1
616.2
506
1
530.6
633
1
407.0
418
1
649.1
506
1
559.1
633
1
428.9
418
1
721.7
506
1
621.2
633
1
476.3
418
2
405.9/405.9
506
1
639.9
633
1
490.7
418
2
472.0/405.9
506
1
696.4
633
1
533.8
418
2
399.4/537.4
506
2
344.5/462.3
633
2
264.0/354.9
418
2
465.5/652.2
506
2
401.0/561.6
633
2
307.2/430.5
418
2
465.5/708.7
506
2
401.0/610.2
633
2
307.2/467.7
ICF
MOCP
XL
WD
800
957.8
800
842.9
450
1281.3
506.3
400
1062.5
422.5
300
846.3
334.3
800/450
—/—
934.4/484.6
700/400
—/—
814.8/423.2
500
1588.4
614.4
450
1317.0
512.0
350
1049.9
405.9
700/700
—/—
761.4/761.4
600/600
—/—
664.8/664.8
500
1363.7
588.7
450
1133.6
493.6
350
901.1
389.1
800/800
—/—
934.4/934.4
700/700
—/—
814.8/814.8
600
1677.3
703.3
500
1393.6
588.6
400
1108.5
464.5
800/800
—/—
946.3/934.4
800/700
—/—
825.6/814.8
700
1683.8
709.8
600
1399.1
594.1
450
1112.8
468.8
800/800
—/—
946.3/934.4
800/800
—/—
825.6/814.8
700
1716.7
742.7
600
1427.6
622.6
450
1134.7
490.7
800
2411.8
952.8
700
2000.1
795.1
500
1593.4
629.4
800
2444.7
985.7
700
2028.6
823.6
600
1615.3
651.3
1000
2451.2
992.2
800
2034.1
829.1
600
1619.6
655.6
600/600
2201.5/2201.5
742.5/742.5
800
2109.4
904.4
600
1677.1
713.1
800/600
2201.5/2201.5
742.5/742.5
800
2109.4
904.4
700
1677.1
713.1
600/700
2195.0/1710.2
736.0/736.2
500/600
1814.0/1422.2
609.0/617.2
400/450
1450.4/1130.4
486.4/486.4
700/800
2195.0/2381.7
736.0/922.7
600/800
1814.0/1974.6
609.0/769.6
500/600
1450.4/1573.7
486.4/609.7
700/1000
2195.0/2438.2
736.0/979.2
600/ 800
1814.0/2023.2
609.0/818.2
500/ 600
1450.4/1611.0
486.4/647.0
5. Wiring for main field supply must be rated 75 C minimum. Use copper for all units.
a. Incoming wire size range for the terminal block is no. 4 AWG (American Wire Gage) to
500 kcmil.
b. Incoming wire size range of non-fused disconnect with MCA up to 599.9 amps is 3/0 to
500 kcmil.
c. Incoming wire size range of non-fused disconnect with MCA from 600 to 799.9 amps is
1/0 to 500 kcmil.
d. Incoming wire size range of non-fused disconnect with MCA from 800 to 1199.9 amps is
250 kcmil to 500 kcmil.
6. Data provided circuit 1/circuit 2 where there are two circuits.
CONTROL CIRCUIT
REC FUSE SIZE
Voltage
MCA and MOCP
(1 Ph, 60 Hz)
700
115
700
115
400
115
350
115
250
115
600/350
115
600/300
115
450
115
400
115
300
115
500/500
115
450/450
115
450
115
400
115
300
115
600/600
115
600/600
115
600
115
450
115
350
115
700/600
115
700/600
115
600
115
500
115
400
115
700/700
115
700/600
115
600
115
600
115
400
115
700
115
600
115
500
115
800
115
700
115
500
115
1000
115
700
115
600
115
500/500
115
800
115
600
115
600/500
115
800
115
600
115
500/600
115
450/600
115
350/400
115
600/800
115
500/700
115
400/500
115
600/800
115
500/700
115
400/600
115
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
50
50
50
50
50
50
50
50
50
39