Carrier Deluxe 38YZA Product Data page 25

Deluxe 12 seer split-system heat pump with puron refrigerant
Hide thumbs Also See for Deluxe 38YZA:
Table of Contents

Advertisement

Heat pump heating performance continued
INDOOR
AIR
–3
Total
Capacity
Pow-
Capacity
(MBtuh)
er
EDB CFM
Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw† Total Int* Kw†
1750 26.3 24.2 3.96 32.1 29.5 4.13 38.1 34.8 4.29 44.7 39.7 4.45 52.3 47.6 4.65 60.8 60.8 4.86 59.0 59.0 4.74 57.0 57.0 4.75
65
2000 26.6 24.5 4.07 32.5 29.9 4.22 38.7 35.2 4.34 45.3 40.3 4.47 53.1 48.3 4.64 61.7 61.7 4.84 59.9 59.9 4.69 58.1 58.1 4.68
2250 26.9 24.7 4.19 32.9 30.3 4.33 39.1 35.7 4.41 45.9 40.8 4.52 53.8 48.9 4.67 62.6 62.6 4.85 60.8 60.8 4.68 59.1 59.1 4.65
1750 25.7 23.6 4.07 31.7 29.2 4.32 37.8 34.5 4.50 44.3 39.3 4.68 51.7 47.1 4.88 60.0 60.0 5.11 58.1 58.1 4.98 56.1 56.1 4.68
70
2000 26.0 23.9 4.18 32.2 29.6 4.40 38.3 34.9 4.55 44.9 39.9 4.70 52.5 47.7 4.88 60.9 60.9 5.08 59.1 59.1 4.93 57.2 57.2 4.90
2250 26.2 24.1 4.29 32.6 30.0 4.50 38.8 35.4 4.62 45.5 40.4 4.74 53.2 48.4 4.90 61.7 61.7 5.08 59.9 59.9 4.91 58.1 58.1 4.87
1750 24.9 22.9 4.15 31.3 28.8 4.49 37.4 34.1 4.72 43.9 38.9 4.92 51.1 46.5 5.14 59.2 59.2 5.37 57.2 57.2 5.22 55.2 55.2 5.22
75
2000 25.1 23.1 4.25 31.8 29.2 4.57 38.0 34.6 4.76 44.5 39.5 4.93 51.9 47.2 5.12 60.2 60.2 5.33 58.2 58.2 5.17 56.3 56.3 5.14
2250 25.3 23.3 4.35 32.2 29.6 4.67 38.4 35.1 4.83 45.0 40.0 4.98 52.6 47.8 5.14 61.0 61.0 5.33 59.1 59.1 5.14 57.2 57.2 5.10
Indoor
Section
Size
FX4ANB
060
40FKA/FK4CNB
006
FB4ANB
070
FC4BNB
070
FV4ANB
006
CC5A/CD5AW
060
CK5A/CK5BX
060
* The Btuh heating capacity values shown are net "integrated'' values from which the defrost effect has been subtracted. The Btuh heating from supplement
heaters should be added to those values to obtain total system capacity.
† The kw values include the compressor, outdoor fan motor, and indoor blower motor. The kw from supplement heaters should be added to these values to
obtain total system kilowatts.
EDB—Entering Dry Bulb
NOTE: The performance shown includes the PressureGuard™ cycling the outdoor fan. The ambient temperature that
the outdoor fan cycles depends on the outdoor/indoor combination, indoor airflow, installation practices, and
system maintenance, all of which affect system performance.
OUTDOOR COIL ENTERING AIR TEMPERATURES °F
7
17
Total
Total
Pow-
Capacity
Pow-
(MBtuh)
er
(MBtuh)
er
38YZA060-31 Outdoor Section With FX4ANB060 Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections.
Heating
Capacity
Power
1.00
0.99
1.00
1.00
1.00
0.97
0.98
27
37
Total
Total
Capacity
Pow-
Capacity
Pow-
(MBtuh)
er
(MBtuh)
Indoor
Section
1.03
COILS + 58U(H,X)V100-20 VARIABLE SPEED FURNACE
0.99
CC5A/CD5AW
1.03
CK5A/CK5BX
1.03
COILS + 58U(H,X)V120-20 VARIABLE SPEED FURNACE
1.00
CC5A/CD5AW
1.08
CK5A/CK5BX
1.04
47
57
Total
Capacity
Pow-
Capacity
er
(MBtuh)
er
(MBtuh)
Heating
Size
Capacity
060
0.97
060
0.98
060
0.97
060
0.98
67
Total
Total
Pow-
Capacity
Pow-
er
(MBtuh)
er
Power
1.06
1.02
1.07
1.03
25