Carrier 38aqs/40rmq heat pump systems

Advertisement

38AQS012,016
Copyright 1999 Carrier Corporation
Product
Data
38AQS008
40RMQ
38AQS/40RMQ
Heat Pump Systems
Nominal Heating: 83,000 to 164,000 Btuh
Nominal Cooling: 7
Heat Pump Systems that Save
Energy and Provide Outstanding
Heating and Cooling All Year
• All-season comfort in any climate
• High energy savings capability
• Suitable for new construction or
replacement
Features/Benefits
System indoor and outdoor
sections offer outstanding
performance in either the
cooling or heating mode
Heat pump system energy
savings opportunity
Electrical energy consumption is
always a prime concern when selecting
an air-conditioning system for a com-
mercial application. An easy, effective
way to save energy is to install a heat
pump. Should your building plans call
for one, consider a matched Carrier
38AQS/40RMQ heat pump system.
These systems not only provide highly
efficient cooling, they also double as a
clean, safe, efficient source of heat. In
fact, they are capable of delivering
approximately 3 units of heat energy
for each unit of electrical power
consumed.
Heat pump uniqueness
The outstanding performance of these
heat pump systems is due to the heat
pump's ability to absorb and transfer
heat — from outdoors to indoors for
heating, and from indoors to outdoors
for cooling. System indoor and out-
door sections operate as evaporators
or condensers, depending on whether
heating or cooling is required. The
heating cycle always starts with the
outdoor coil absorbing heat from the
1
/
to 15 Tons
2
Form 38AQS-4PD

Advertisement

Table of Contents
loading

Summary of Contents for Carrier 38AQS008

  • Page 1 An easy, effective way to save energy is to install a heat pump. Should your building plans call for one, consider a matched Carrier 38AQS/40RMQ heat pump system. These systems not only provide highly 38AQS012,016 efficient cooling, they also double as a clean, safe, efficient source of heat.
  • Page 2 If the thermostat is not calling for Features to consider, defrosting, another 60 minutes must 38AQS008 units pass before defrosting begins. Controls for performance effi- ciency — The 38AQS008 unit offers...
  • Page 3: Table Of Contents

    Application Data .........33-36 Guide Specifications — 38AQS008 Outdoor Units ....37,38 Guide Specifications —...
  • Page 4: Model Number Nomenclature

    6 — 460-3-60 *Size 008 only. †For 40RMQ008 units with single-phase motors, YC and WD options denote standard motor and high-static drive. Quality Assurance Approvals: ISO 9001 EN 29002 BS5750 PART 2 ANSI/ASQC Q92 38AQS008 UNITS 38AQS012,016 AND 40RMQ UNITS...
  • Page 5: Ari Capacities

    Lo-Temp Heating Standard: 70 F db indoor entering-air temperature and 17 F wb/15 F db entering-air outdoor unit. 38AQS008, 012 and 40RMQ008, 012 are rated in accordance with ARI Standard 210/240-94. 38AQS016 and 40RMQ016 are rated in accordance with ARI Standard 340/360-93.
  • Page 6: Physical Data

    Physical data OUTDOOR UNITS UNIT 38AQS NOMINAL CAPACITY (tons) OPERATING WT (lb) REFRIGERANT (R-22) Operating Charge (lb)* 19.5 COMPRESSOR 06DA818 06DF824† 06DF537† Cylinders 1750 Oil Charge (pt) (ea) OUTDOOR FANS Propeller; Direct Drive 1100 1075 Blade Diameter (in.) Motor Hp 6500 11,000 0.96...
  • Page 7 INDOOR UNITS UNIT 40RMQ NOMINAL CAPACITY (Tons) OPERATING WEIGHT (lb) Base Unit with TXV Plenum FANS Qty...Diam. (in.) 1...15 1...15 2...15 3000 4000 6000 Nominal Airflow (cfm) Airflow Range (cfm) 2250-3750 3000-5000 4500-7500 Nominal Motor Hp (Standard Motor)* 208/230-1-60 — —...
  • Page 8: Options And Accessories

    Indoor units — factory-installed options perature down to –20 F. Alternate fan motors and drives are available to pro- Carrier’s line of thermostats provide both programma- vide the widest possible range of performance. ble and non-programmable capability with the new Prepainted steel units are available from the factory for Debonair™...
  • Page 9 The sensor signals the economizer to open when air and “free” cooling if outside ambient temperature and the CO level in the space exceeds the set point. A Carrier humidity are suitable. Can also be used in conjunction with Comfort System programmable thermostat can also be...
  • Page 10 Options and accessories (cont) CARRIER THERMOSTATS DEBONAIR™ COMMERCIAL PROGRAMMABLE TEMP SYSTEM THERMOSTAT WITH TIMECLOCK THERMOSTAT Carrier ® COOL AUTO HEAT COMMERCIAL ELECTRONIC THERMOSTAT NON-PROGRAMMABLE THERMOSTAT...
  • Page 11 40RMQ WITH HOT WATER OR STEAM COIL 40RMQ WITH DISCHARGE PLENUM, RETURN GRILLE AND SUBBASE HOT WATER OR STEAM COIL DISCHARGE PLENUM RETURN-AIR GRILLE SUBBASE COIL UNIT FAN COIL UNIT 40RMQ WITH ECONOMIZER 40RMQ WITH CONDENSATE DRAIN TRAP ECONOMIZER FAN COIL UNIT...
  • Page 12: Dimensions - Outdoor Units

    Dimensions — outdoor units 38AQS008 DIMENSION CHART UNIT WITH UNIT WITH UNIT ALUMINUM-FIN COIL COPPER-FIN COIL 38AQS Dim. A Dim. B Dim. A Dim. B NOTES: 1. Dimensions in [ ] are in millimeters. ″ ″ 1′-8″ 1′-5″ 1′-9 1′-4 [508.0]...
  • Page 13 38AQS012,016...
  • Page 14: Dimensions - Indoor Units

    • Rear: 3″ • Front: 2′-6″ • Right Side: 2′-6″ • Left Side: 2′-6″ • Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory supplied and field installed. UNIT WEIGHT UNIT...
  • Page 15 • Rear: 3″ • Front: 2′-6″ • Right Side: 2′-6″ • Left Side: 2′-6″ • Local codes or jurisdiction may prevail. 4. Liquid piping not supplied by Carrier. 5. Duct flange is factory supplied and field installed. UNIT WEIGHT UNIT (lb)
  • Page 16 Dimensions — indoor units (cont) 40RMQ008,012 WITH ELECTRIC HEATER ACCESSORY 40RMQ016 WITH ELECTRIC HEATER ACCESSORY NOTE: Dimensions in [ ] are in millimeters. UNIT SIZE 40RMQ ″ ″ ″ ″ ″ ″ ″ ″ 1′-3 4′-6 2′-1 10′- 1′-4″ 1′-4 1′-6 1′- [387.4]...
  • Page 17: Selection Procedure

    Selection procedure (with example) I. Determine cooling heating load Select an electric heater that satisfies the voltage designation and the supplemental heat requirement. requirements. Refer to the Electric Heater Data — Indoor Units Given: table, page 26. The supplemental heating load Total Cooling Load (TC) .
  • Page 18: Performance Data

    1. To obtain total outdoor unit power, add outdoor fan kW shown to compressor draw: 38AQS008 — .96 kW; 38AQS012 and 016 — 1.4 kW. 2. Ratings are without supplementary heat and are based on 70 F db air entering indoor unit.
  • Page 19 4. Capacities are based on 25 actual ft (40 equivalent ft) of interconnecting piping sized to the outdoor unit field connections. (Equivalent length is equal to the actual length plus a 50% allowance for fitting losses.) For other equivalent lengths, refer to the Carrier System Design Manual, Part 3, for line losses.
  • Page 20 Performance data (cont) COMBINATION RATINGS (cont) NET CAPACITIES — HEATING 38AQS008 WITH 40RMQ008 38AQS016 WITH 40RMQ016 Temp (F) Temp Air Entering Outdoor Unit (F) Temp (F) Temp Air Entering Outdoor Unit (F) Air Ent Airflow Air Ent Airflow Indoor (Cfm)
  • Page 21 INDOOR UNIT ACCESSORY COILS — HYDRONIC INDOOR UNIT ACCESSORY COILS — HEATING HEATING CAPACITIES CORRECTION FACTORS 1-ROW 2-ROW HOT WATER COIL UNIT AIRFLOW STEAM* HOT WATER COIL† Entering-Air Temp (F) Water Temp Ent Water 40RMQ (Cfm) Cap. Cap. Drop (F) Temp (F) 2,250 174.0...
  • Page 22 Performance data (cont) INDOOR UNIT FAN PERFORMANCE DATA — 1.4-2.4 ESP EXTERNAL STATIC PRESSURE (in. wg) UNIT AIRFLOW 40RMQ (Cfm) 2,250 1.06 1.16 1.27 1001 1.37 1042 1.47 — — 1.22 1.33 1.43 1027 1.54 1067 1.65 — — 2,600 3,000 1.43 1.54...
  • Page 23: Typical Piping And Wiring

    †Field supplied. 5. Filter drier must be bi-flow type suited for heat pump duty. 6. Internal factory-supplied TXVs and check valves not shown. NOTES: 1. All piping must follow standard refrigerant piping techniques. Refer to Carrier System Design Manual for details.
  • Page 24 Typical piping and wiring (cont) 38AQS012,016 AND 40RMQ012,016 (016 SIZE UNITS SHOWN) NOTES: LEGEND 1. All piping must follow standard refrigerant piping techniques. Refer to Carrier System NEC — National Electrical Code Design Manual for details. — Thermostatic Expansion Valve 2.
  • Page 25: Electrical Data

    Electrical data OUTDOOR UNITS VOLTAGE RANGE COMPR FAN MOTORS POWER SUPPLY UNIT V-PH-Hz No. of Min Ckt MOCP 38AQS Fans Amps (Amps) Fan No. 1 Fan No. 2 208/230-3-60 31.5 — 42.5 460-3-60 15.7 — 21.0 208/230-3-60 43.6 62.5 460-3-60 20.0 29.1 575-3-60...
  • Page 26 Electrical data (cont) ELECTRIC HEATER DATA — INDOOR UNITS ELECTRIC HEATERS(S) FAN MOTOR UNIT HEATER Nominal Actual Capacity (kW) V-PH-Hz MCA* MOCP* 40RMQ PART NO. Capacity Stage 1 Stage 2 Total (kW) 2.4† 1.79 11.0 — 12.0 28.8 1.79 — 12.0 21.5 CAELHEAT001A00...
  • Page 27 ELECTRIC HEATER DATA, INDOOR UNITS (cont) ELECTRIC HEATERS(S) FAN MOTOR UNIT HEATER Nominal Actual Capacity (kW) V-PH-Hz MCA* MOCP* 40RMQ PART NO. Capacity Stage 1 Stage 2 Total (kW) 2.76 10.2 10.0 — 10.0 24.1 42.8 CAELHEAT016A00 240-3-60 3.73 12.8 10.0 —...
  • Page 28: Controls

    Controls Sequence of operation — 38AQS008 outdoor The indoor fans, outdoor fans, and compressor start unit with 40RMQ008 indoor unit within 5 minutes (due to compressor time delay) on com- mand from the controlling thermostat in either the Cooling When power is supplied to unit, the transformer (TRAN) is or the Heating mode of operation.
  • Page 29: Typical Control Wiring Schematic

    — Heater Relay T’STAT — Thermostat NOTES (38AQS008 Unit) 1. If any of the original wire furnished must be replaced, it must be 5. Three-phase motors are protected under primary single-phasing replaced with type 90 C wire or its equivalent.
  • Page 30 Typical control wiring schematic (cont) 38AQS008...
  • Page 31 38AQS012,016 — 208/230-3-60...
  • Page 32 Typical control wiring schematic (cont) 38AQS012,016 — 460-3-60, 575-3-60 COMPONENT ARRANGEMENT...
  • Page 33: Application Data

    40RMQ Application data Operating limits General Maximum operating temperature ....115 F Select equipment to match or to be slightly less than peak Minimum return-air temperature ....55 F load.
  • Page 34 Application data (cont) Liquid line solenoid valve (38AQS008 only) MINIMUM OUTDOOR-AIR OPERATING TEMPERATURE* Addition of a liquid solenoid valve (LLSV) is recommended when the piping system length exceeds 75 feet. The LLSV MINIMUM OUTDOOR COMPR SATURATED TEMPERATURE (F) must be a bi-flow type suited for use in heat pump systems.
  • Page 35 MAXIMUM VERTICAL SEPARATION* DISTANCE (FT) OUTDOOR UNIT INDOOR UNIT Indoor Unit 38AQS 40RMQ Above Outdoor Unit Below Outdoor Unit *Vertical distance between indoor and outdoor units. FACTORY-INSTALLED NOZZLE AND DISTRIBUTOR DATA — INDOOR UNITS FEEDER TUBES UNIT DISTRIBUTOR NOZZLE PER DISTRIBUTOR 40RMQ Qty...Part No.
  • Page 36 Application data (cont) STANDARD DRIVE DATA — INDOOR UNITS HIGH-STATIC DRIVE DATA — INDOOR UNITS UNIT 40RMQ UNIT 40RMQ MOTOR DRIVE MOTOR DRIVE Motor Pulley Pitch Diameter 2.8-3.8 3.4-4.4 2.8-3.8 Motor Pulley Pitch Diameter 3.4-4.4 3.4-4.4 4.3-5.3 Pulley Factory Setting Pulley Factory Setting Full Turns Open Full Turns Open...
  • Page 37: Guide Specifications - 38Aqs008 Outdoor Units

    Size Range: 83,000 Nominal Btuh Heating to compressor and control compartments. Nominal Tons Cooling 4. A refrigerant accumulator with a fusible plug Carrier Model Number: 38AQS008 relief shall be installed in the cabinet. Part 1 — General 5. Lifting holes shall be provided to facilitate 1.01 SYSTEM DESCRIPTION...
  • Page 38 A shut-off valve shall be pro- switch, timeclock, LCD display, °F/°C capa- vided for each gage. bility, and CCN (Carrier Comfort Network) 4. Coil Guard: compatibility. Grille shall protect condenser coil from damage c. Commercial Electronic Thermostat with by large objects or vandalism.
  • Page 39: Guide Specifications - 38Aqs012,016 Outdoor Units

    2. Fan venturi housings and guards shall be assem- 10 and 15 Nominal Tons Cooling bled on the unit. Carrier Model Number: 38AQS012,016 3. A removable panel or hinged door shall be pro- Part 1 — General vided for access to the compressor and control 1.01 SYSTEM DESCRIPTION...
  • Page 40 Guide specifications — 38AQS012,016 outdoor units (cont) F. Controls and Safeties: 3. Mounting Legs: Operating controls and safeties shall be factory Legs shall hold the unit approximately 18 in. off the ground to allow space for drainage. selected, assembled, and tested. Minimum control functions shall be as listed below: 4.
  • Page 41 60° of 65 ing multi-stage thermostat with fan switch, to 90% per ASTM D523-89. Uniform dry timeclock, LCD display, °F/°C capability, film thickness from 0.8 mil to 1.2 mil on all (Carrier Comfort Network) surface areas including fin edges. Superior compatibility.
  • Page 42: Guide Specifications - Indoor Units

    -in. fire-retardant material. Insulation shall to 15 Tons, Nominal Cooling contain an EPA-registered immobilized antimi- Carrier Model Numbers: 40RMQ crobial agent to effectively resist the growth of Part 1 — General bacteria and fungi as proven by tests in accor- 1.01 SYSTEM DESCRIPTION...
  • Page 43 Heaters for nominal 240, 480, or 575-volt, timeclock, LCD display, °F/°C capability, 3-phase, 60 Hz power supply shall be factory- and CCN (Carrier Comfort Network) com- supplied for field installation as shown on the patibility. equipment drawings. Electric heat assembly c.
  • Page 44 Carrier Corporation • Syracuse, New York 13221 11-99 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 1 4 Book 2 Pg 44 Catalog No. 523-763 Printed in U.S.A.