High-Wall Type
How to remove the drains cap
Clip the drain cap by needle-nose pliers and pull out.
How to fix the drains cap
1) Insert hexagonal wrench (dia. 0.16" (4 mm)) in a centre head.
0.16" (4 mm)
2) Firmly insert drains cap.
Firmly insert the drain hose and drain cap; otherwise, water may leak.
How to remove the drain hose
1) Remove the front panel.
2) Remove the screws of drain hose.
3) Pull out the drain hose.
▼ In case of right or left piping
• After scribing slits of the front panel with a knife or a marking-off pin, cut them with a pair of nippers or an
equivalent tool.
11-EN
No gap
Insert a hexagon wrench
(0.16" (4 mm))
CAUTION
Slit
– 11 –
Do not apply lubricating oil (refrigerant
machine oil) when inserting the drain cap.
Application causes deterioration and drain
leakage from the plug.
How to fix the drain hose
1) Put the drain hose.
2) Screw the drain hose to the indoor unit.
3) Install the front panel.