Three-phase 500V class
Inverter
Transmission noise
IEC61800-3 C2
(EN55011
Group. 1 Class A)
(Length of motor
connecting cable: Max. 5
m)
VFS11-4004PL
With a built-in filter
VFS11-4007PL
With a built-in filter
VFS11-4015PL
With a built-in filter
VFS11-4022PL
With a built-in filter
VFS11-4037PL
With a built-in filter
VFS11-4055PL
-
VFS11-4075PL
-
VFS11-4110PL
-
VFS11-4150PL
-
Single-phase 240V class
Inverter
Transmission noise
IEC61800-3 C2
(EN55011
Group. 1 Class A)
(Length of motor
connecting cable: Max. 5
m)
VFS11S-2002PL
With a built-in filter
VFS11S-2004PL
With a built-in filter
VFS11S-2007PL
With a built-in filter
VFS11S-2015PL
With a built-in filter
VFS11S-2022PL
-
Note : For 600V models compliant with EU standards, contact your nearest Toshiba inverter distributor.
(2)
Use shielded power cables, such as inverter output cables, and shielded control cables. Route the cables
and wires so as to minimize their lengths. Keep a distance between the power cable and the control cable
and between the input and output wires of the power cable. Do not route them in parallel or bind them
together, instead cross at right angle.
(3)
Install the inverter and the filter on the same metal plate. It is more effective in limiting the radiation noise to
install the inverter in a sealed steel cabinet. Using wires as thick and short as possible, earth the metal plate
and the control panel securely with a distance kept between the earth cable and the power cable.
(4)
Route the EMI filter input and output wires apart from each other.
(5)
To suppress radiation noise from cables, ground all shielded cables through a noise cut plate.
It is effective to earth shielded cables in the vicinity of the inverter, cabinet and filter (within a radius of 10cm
from each of them). Inserting a ferrite core in a shielded cable is even more effective in limiting the radiation
noise.
(6)
To further limit the radiation noise, insert a zero-phase reactor in the inverter output line and insert ferrite
cores in the earth cables of the metal plate and cabinet.
Combination of inverter and filter
Transmission noise
Transmission noise
IEC61800-3 C3
IEC61800-3 C1
(EN55011
Group. 2 Class A)
Group 1 Class B)
(Length of motor
(Length of motor
connecting cable: Max. 5
connecting cable: Max.
m)
-
-
-
-
-
With a built-in filter
With a built-in filter
With a built-in filter
With a built-in filter
Combination of inverter and filter
Transmission noise
Transmission noise
IEC61800-3 C3
IEC61800-3 C1
(EN55011
Group. 2 Class A)
Group 1 Class B)
(Length of motor
(Length of motor
connecting cable: Max. 5
connecting cable: Max.
m)
-
-
-
-
With a built-in filter
49
E6581160
Transmission noise
IEC61800-3 C2
(EN55011
(EN55011
Group 1 Class A)
(Length of motor
connecting cable: Max.
20 m)
50 m)
EMFS11-4015BZ
EMFS11-4015BZ
EMFS11-4015BZ
EMFS11-4025CZ
EMFS11-4025CZ
EMFS11-4047DZ
EMFS11-4047DZ
EMFS11-4049EZ
EMFS11-4049EZ
Transmission noise
IEC61800-3 C2
(EN55011
(EN55011
Group 1 Class A)
(Length of motor
connecting cable: Max.
20 m)
50 m)
EMFS11S-2009AZ
EMFS11S-2009AZ
EMFS11S-2009AZ
EMFS11S-2016BZ
EMFS11S-2022CZ
6