Power Supply Wiring - Extron electronics MTP 1500RL 15HD A SEQ User Manual

Extended distance twisted pair receiver
Hide thumbs Also See for MTP 1500RL 15HD A SEQ:
Table of Contents

Advertisement

Power Supply Wiring

NOTE:
Wire the supplied male power connector (plug) as in shown below.
POWER
12V
1.0 A MAX
Figure 5.
NOTES: • The length of the exposed wires in the stripping process is critical.
CAUTION: Power supply voltage polarity is critical. Incorrect voltage polarity can
To verify the polarity before connection, plug in the power supply with no load and
check the output with a voltmeter.
WARNING:
As an alternative, an Extron PS 124 Universal 12 VDC Power Supply, part #60-1022-01,
can power multiple MTPs or other Extron 12 VDC devices using only one AC power
connector..
This product is intended to be supplied by a UL Listed power supply and
output rated at 12 VDC, 1 A.
Rear Panel
Power Receptacle
DC Power Cord
Captive Screw Connector
Ground
+12 VDC
AC Power Cord
External
Power Supply
(12 VDC, 1 A )
Power Connector Wiring
The ideal length is 3/16 inches (5 mm). If it is longer, the exposed wires
may touch one another, causing a short circuit between them. Any shorter
and the wires could be easily pulled out even if tightly fastened by the
captive screws.
• Do not tin the wires. Tinned wire does not hold its shape and can become
loose over time.
damage the power supply and the product. Identify the power cord
negative lead by the ridges on the side of the cord.
The two power cord wires must be kept separate while the power
supply is plugged in. Remove power before wiring.
MTP 1500RL 15HD A SEQ • Installation and Setup
3/16"
(5 mm) Max.
SECTION A–A
Smooth
Ridges
A
A
Tie Wrap
Power Supply
Output Cord
2-Pole Captive Screw
Connector
6

Advertisement

Table of Contents
loading