Summary of Contents for Extron electronics MTP 1500RL 15HD RS Series
Page 1
MTP 1500RL 15HD RS and MTP 1500RL 15HD RS SEQ Extended Distance Mini Twisted Pair Receivers 68-1555-01 Rev. A 10 09...
Page 2
Precautions Safety Instructions • English Warning Power sources • This equipment should be operated only from the power source This symbol is intended to alert the user of important indicated on the product. This equipment is intended to be used with a main power operating and maintenance (servicing) instructions in system with a grounded (neutral) conductor.
(bi-/tri-level), S-video, or composite video signals over twisted pair cables. The Extron MTP 1500RL 15HD RS series is a half rack size line of basic twisted pair receivers that are fully compatible with all MTP transmitters, distribution amplifiers, matrix switchers and associated video accessories.
1500 1600x1200 <900 >1000 1500 1920x1200 <800 >900 1200 2048x1080 <800 >900 1200 720p <900 >1000 1500 1080i <900 >1000 1500 1080p <900 >1000 1500 The transmitter and receiver are designed for and perform best with Extron Enhanced Skew-Free A/V cable terminated in accordance with the TIA/EIA T568A standard (see page 9). CAT 5 cables are acceptable but less preferable. We also recommend the use of preterminated and tested cables. Cables terminated on site should be tested before use to ensure that they comply with Category 5 specifications. MTP 1500RL 15HD RS Series • Introduction...
Extron MTP 1500RL 15HD RS SEQ Extended Distance Mini Twisted Pair Receiver with Loop-Through and Skew EQ Flat Panel Display RS-232 S SE 15 H 15 00 M TP -2 32 Extron RGBHV MTP 1500RL 15HD RS SEQ M TP Extended Distance Mini Twisted Pair Receiver M TP W ER...
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay particular attention to supply connections other than direct connections to the branch circuit (e.g., use of power strips). MTP 1500RL 15HD RS Series • Installation...
Mount the MTP using two 4-40 x 3/16" screws in opposite (diagonal) corners to secure the MTP to the shelf. DO NOT stack units on top of one another as this may cause the units to overheat. Install false faceplate(s) or other unit(s) to the rack shelf. MTP 1500RL 15HD RS Series • Installation...
MTP transmitter to the 3-pole captive screw connector (wired as below) for RS-232 for bidirectional or unidirectional communication up to 1,000 feet (maximum). Connected RS-232 MTP Reciever Device Pins Pins Receive Transmit Ground Figure 4 — RS-232 connector wiring MTP 1500RL 15HD RS Series • Installation...
Page 11
The receiver being configured is the last receiver in a daisy-chained system. • BI-232 switch — Set this up (ON) for bidirectional or down (off) for unidirectional communication. N For best image quality for distances over 1000 feet, set the BI-232 DIP switch to unidirectional (down). When daisy-chaining units, this switch should be set to off for unidirectional RS-232 communication. MTP 1500RL 15HD RS Series • Installation...
Supply (part #60-1022-01) can power multiple MTPs or other Extron 12 VDC devices using only one AC power connector. Insert the wired plug into the power connector on the rear panel. Do not power on the device at this time. MTP 1500RL 15HD RS Series • Installation...
Serial Data - Serial Data - Serial Data - Blue/H Sync + Blue/C Sync + No Signal No Signal B-Y + Blue/H Sync - Blue/C Sync - No Signal No Signal B- Y - MTP 1500RL 15HD RS Series • Installation...
Front Panel Controls and Indicators Front panel features on the MTP 1500RL 15HD RS series receivers are shown below. LEVEL PEAKING SELECT GREEN BLUE MIN/MAX ADJUST MTP 1500RL SERIES DELAY LEVEL PEAKING MIN/MAX MTP 1500RL SERIES Figure 7 — MTP receiver series front panels Power LED —...
This equalizes both the low frequency (white field) and the high frequency (alternating black/white field) to the same video level for best results. Do not over-peak the signal. MTP 1500RL 15HD RS Series • Installation...
Use a Tweeker or other small screwdriver to press the Select button one more time to save the most recent adjustment or allow the 10-second timeout to elapse. If the remaining color is left shifted, repeat step 3. MTP 1500RL 15HD RS Series • Installation...
Add a skew compensation cable equal to the length of pair skew to the receiver’s output. • Install an SEQ 100 15HD Skew Equalizer on the receiver’s video output and adjust the skew for the leading video image. MTP 1500RL 15HD RS Series • Installation...
Output level ........0.3 Vp-p for component video (bi-level sync) 0.6 Vp-p for component video (tri-level sync) TTL: 4.0 V to 5.0 V p-p, unterminated for RGBHV, RGBS Output impedance ......110 ohms Polarity..........Positive or negative (switch-selectable) MTP 1500RL 15HD RS Series • Specifications...
Page 19
(2.5 cm H x 22.2 cm W x 15.2 cm D) (Depth excludes connectors.) Product weight ......1 lb (0.5 kg) Shipping weight ......2 lbs (1 kg) Vibration ......... ISTA 1A in carton (International Safe Transit Association) MTP 1500RL 15HD RS Series • Specifications...
Page 20
Regulatory compliance Safety ........CE, c-UL, UL EMI/EMC ......CE, C-tick, FCC Class A, ICES, VCCI MTBF ..........30,000 hours Warranty ......... 3 years parts and labor All nominal levels are at ±10%. Specifications are subject to change without notice. MTP 1500RL 15HD RS Series • Specifications...
CAT 6 jack (black), Qty 10 100-476-01 CAT 6 jack (red), Qty 10 100-477-01 100-478-01 CAT 6 jack (blue), Qty 10 CAT 6 jack (orange), Qty 10 100-479-01 CAT 6 jack (gray), Qty 10 100-480-01 MTP 1500RL 15HD RS Series • Specifications...
Page 22
In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.