Cooling System Specifications; Vehicle With Air Conditioning - CITROEN C8 2002 Handbook

Table of Contents

Advertisement

Engine type
Circuit capacity
Radiator surface
Pressurisation
Opening of thermostatic
regulator
Cooling fan
1st speed
2nd speed
3rd speed
Aircon cut-out
Warning
Post-cooling
(*) = (*) = With automatic gearbox : 10.2 litres ; (**) = With automatic gearbox = 1x460W ; (***) = With automatic gearbox = 1x350W+1x300W

COOLING SYSTEM SPECIFICATIONS

Engines : RFN – 3FZ – XFW – RHT – 4HW
2.0i 16V
2.2i 16V
RFN
3FZ
7 litres
7.2 litres
89°C
1x350W (**)
1x350W
97°C or 10 Bars
in aircon circuit
101°C or 17 Bars
in aircon
105°C or 22 Bars
in aircon circuit
115°C
69

Vehicle with air conditioning

3.0i 24V
XFW
RHT - RHW
10.5 litres
25 dm
3
1.4 Bar
78°C
1x350W +1x300W
1x400W +1x300W (***)
97°C or 10 Bars
101°C or 17 Bars
in aircon
circuit
112°C
118°C
No
2.0 HDi
2.2 HDi
4HW
10 litres (*)
11.3 litres
89°C
1x460 + 1x300W
97°C or 10 Bars
in aircon circuit
105°C or 22 Bars
in aircon
in aircon
circuit
circuit
115°C

Advertisement

Table of Contents
loading

Table of Contents