Sharp GX10i Service Manual page 67

Digital mobile phone
Hide thumbs Also See for GX10i:
Table of Contents

Advertisement

1) Basic Operation Test
<Startup and initial condition>
Fit a battery or a dummy battery in the set. Hold down the "End/Power" key to start up in the general mode. Then enter
AT+XDIAG without pressing any key.
Back light OFF
After startup, "H/W CHECK ∗ GX-10i ∗" is displayed.
When adjusting by the AT command, be sure to perform the LDDEVPRM command before adjustment and the SVDEVPRM
command after adjustment.
Incoming/Outgoing Serial Signal Format for Basic Operation Test
Incoming Serial Signal Outgoing Serial Signal
Item
Command
FROM to
LDDEVPR
SRAM
M
Checking
LED
LCD back
light voltage
Measuring
OUT32K
RTC clock
Battery
BATVAL
voltage
check
RTC Test
RTCWR
(Writing)
RTC Test
RTCRD
(Reading)
Temperature
TMPAD
A/D
Adjustment
Temperature
TMP
check
CONFIDENTIAL
Start up in the general function test mode. (3 sec. until startup)
n
Response
None
LDDEVPRM OK
LDDEVPRM NG
5
LEDn (n=0, 1, 2, 3, 4)
4
3
2
1
0
1
OUT32Kn
0
None
Okn.nn
yymm
OK
ddhh
mmss
None
RTC yymmddhhmmss
4
ADSETOK
3
TMPADH <Readout
AD value>
2
TMPADL <Readout AD
value>
1
TMPADRDY
n
TMPnxx: Temperature
NG: Except 0 – 50 ˚C
Contents
FROM to SRAM extension.
The contents of FROM are dam-
aged.
Sub-screen display back light.
Key back light LED.
Red LED lights up.
Green LED lights up.
Main-screen display back light
lights up.
All LEDs light off. *1
32 kHz Output (MON Output)
32 kHz Stop (Returned to
ALT1)
Reading down to the last two
digits of voltage.
Writing time of day
"yymmddhhmmss" to RTC. *2
Reading time of day
"yymmddhhmmss" from RTC.
*2
Adjustment mode ended. *3
2.2 V Measurement started.
0.4 V Measurement started.
Adjustment mode started.
Temperature readout. (0 ˚C
min.)
n=1: Camera
n=2: Battery
2 – 63
GX10i
Test Method
Before adjustment perform this
command to output the adjustment
value stored in FROM to SRAM.
Checking that LEDs light up.
LED1: Main-screen display
back light lights up.
LED2: Green LED lights up.
LED3: Red LED lights up.
LED4: Key back light lights up.
LED0: All LEDs light off.
Checking frequency of the real time
clock.
Normal: When OUT32K1 is transmitted,
TP205 frequency is 32.768 kHz ±1.11
kHz.
Reading the voltage of the battery
power line. BATVAL is transmitted,
"OK" and the voltage value are
returned.
Writing time to the clock.
When RTCWR yymmddhhmmss is
transmitted, yy (year), mm (month),
mm (hour), and ss (minute) are written.
Reading time of the clock. When
RTCRD is transmitted, time of day is
read out.
Refer to the "Adjustment procedures
after replacement of parts" on pages
2 – 36 and 2 – 37.
Reading temperature measured by
the temperature sensor.
When TMP is transmitted, TM and
temperature are returned. In case of
other than 0 – 50 ˚C, "NG" is returned.

Hide quick links: