Detachments; Rav-Sp40 * Atp - Toshiba RAV-SP454ATP-E Service Manual

Split type outdoor unit
Hide thumbs Also See for RAV-SP454ATP-E:
Table of Contents

Advertisement

10-1. RAV-SP40
No.
Part name
Common
1
procedure
SVM-12085_051-114.indd 83
SVM-12085_051-114.indd 83

10. DETACHMENTS

ATP
, SP45
ATP
, SP56
*
*
*
*
Procedure
CAUTION
Never forget to put on the gloves at working
time, otherwise an injury will be caused by
the parts, etc.
1. Detachment
1) Stop operation of the air conditioner, and
turn off the main switch of the breaker for
air conditioner.
2) Remove the valve cover.
(ST1T Ø4 × 8L, 3 pcs.)
After removing screw, remove the valve
cover pulling it downward.
3) Remove wiring cover
(PT2T Ø4 × 10L, 1 pc.), and then remove
connecting cable.
4) Remove the upper cabinet.
(ST1T Ø4 × 8L, 5 pcs.)
After taking off screws, remove the
upper cabinet pulling it upward.
2. Attachment
1) Attach the waterproof cover.
CAUTION
Be sure to attach a waterproof cover.
If it is not attached, there is a possibility that
water enters inside of the outdoor unit.
2) Attach the upper cabinet.
(ST1T Ø4 × 8L, 5 pcs.)
Hook the rear side of the upper cabinet
to claw of the rear cabinet, and then put
it on the front cabinet.
3) Perform cabling of connecting cables, and
fix with cord clamp.
(BT2T Ø4 × 12L, 3 pcs.)
4) Attach the wiring cover.
(PT2T Ø4 × 10L, 1 pc.)
5) Attach the valve cover.
(ST1T Ø4 × 8L, 3 pcs.)
ATP
*
*
Upper cabinet
– 83 –
FILE NO. SVM-12085
Remarks
Valve
cover
Wiring
cover
Water-proof
cover
Front cabinet
12/06/12 11:15 AM
12/06/12 11:15 AM

Hide quick links: