Fireplace & Framing Dimensions; Fireplace Framing - MHSC BVSTNSC Installation & Operating Instructions Manual

B-vent specialty series natural vent gas fireplaces
Table of Contents

Advertisement

B-Vent Specialty Gas Fireplaces
Rough 
Opening
Height
42 "
42 "
3
"
Figure 1 -
Fireplace & Framing Dimensions

FIREPLACE FRAMING

It is best to frame your fireplace after it is positioned and
the vent system installed. Use 2 x 4's and frame to local
building codes.
To install the fireplace facing flush with the finished wall,
position the framework to accommodate the thickness of
the finished wall.
It is not necessary to install a hearth extension with this
fireplace system.
The junction box should be wired to the electrical system
at the time of installation of the fireplace. Wiring must be
performed by a qualified person in a manner to conform
with National Electrical Code ANSI/NFPA 70 and all ap-
plicable local codes.
6
Gas Line 
Access
37 " 
Gas Line 
Access
13
"
22 "
24 "
FIREPLACE & FRAMING DIMENSIONS
6" B-Vent flue
4" O.A. Inlet
12 "
19"
7 " 
22 " 
7 " 
36" 
1" 
38" 
38 " Rough Opening
Width - Peninsula
39" Rough Opening
 Width - See-thru
Always check and make sure power is OFF
1938
before attempting to install or service any
BVST dims
electrical wiring or components.
Do not fill spaces around firebox with in-
sulation or other materials. This could
cause a fire.
Rough
Opening
Depth
23 "
40 " 
1" 
20301938