Product Features; High Elevations; Gas Pressures; Gas Specifications & Orifice Size - MHSC BVSTNSC Installation & Operating Instructions Manual

B-vent specialty series natural vent gas fireplaces
Table of Contents

Advertisement

PRODUCT FEATURES

PRODUCT SPECIFICATIONS
This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
This appliance is not for use with solid fuels.
The appliance must be installed in accordance with
local codes if any. If none exist use the current instal-
lation code, ANSI Z223.1/NFPA 54 in the US and
CSA B149 in Canada.
The appliance must be properly connected to a vent-
ing system.
The appliance is not approved for closet or recessed
installations.

HIGH ELEVATIONS

Input ratings are shown in BTU per hour and are cer-
tified without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, in-
stallation must be in accordance with the current ANSI
Z223.1/NFPA 54 and/or local codes having jurisdic-
tion.
In Canada, please consult provincial and/or local au-
thorities having jurisdiciton for installation at elevations
above 4,500 feet (1,370 m).
20301938

GAS PRESSURES

Inlet Minimum
Inlet Maximum
Manifold Pressure
GAS SPECIFICATIONS & ORIFICE SIZE
Min. Input
Model
Fuel
BTU/h
BVSTNSC
Nat.
29,000
BVPNSC
Nat.
29,000

BEFORE YOU START

Read this homeowner manual thoroughly and follow all
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any dam-
age is found. Do not install any unit with damaged, incom-
plete, or substitute parts. Check your packing list to verify
that all listed parts have been received. You should have
the following:
Fireplace (Firebox and Burner System)
Log Set
Rock Wool
Switch Cover Plate
Ziplock Bag 2" x 3" x 3"
ITEMS REQUIRED FOR INSTALLATION
Phillips Screwdriver
Hammer
Saw and/or saber saw
Electric Drill and Bits
Pliers
Square
Caulking Material (Noncombustible)
Fireplace Surround Material (Noncombustible)
Piping Complying with Local Codes
Pipe Sealant Approved for use with Propane/LPG
(Resistant to Sulfur Compounds)
B-Vent Specialty Gas Fireplaces
Natural
4.5" w.c.
7.0" w.c.
3.5" w.c.
Max.Input
Orifice
BTU/h
Size
42,000
#29 (.136")
42,000
#29 (.136")
Volcanic Rock
White Toggle Switch
Plastic Bag (1)
Framing Materials
Wall Finishing Materials
Level
Tee Joint
Measuring Tape
Pipe Wrench
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bvpnsc

Table of Contents