Inspection And Service - Worcester GREENSTAR 25Si Instruction Manual

Wall hung rsf gas fired condensing combination boiler
Table of Contents

Advertisement

CAUTION: TURN OFF THE GAS SUPPLY AND ISOLATE THE MAINS
S U P P LI E S B E FOR E STARTI NG ANY WOR K AN D OB S E RVE ALL
RELEVANT SAFETY PRECAUTIONS.
IMPORTANT: AFTER REPLACEMENT OF ANY COMPONENTS ALWAYS
CHECK FOR GAS SOUNDNESS WHERE RELEVANT AND CARRY OUT
FUNCTIONAL CHECKS AS DESCRIBED IN COMMISSIONING.
DAMAGED O-RINGS OR GASKETS MUST BE REPLACED.
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 25Si/30Si
8 716 115 165a (06/2008)

INSPECTION AND SERVICE

I M P ORTANT: Any service work
must be carried out by competent
registered engineers such as
British Gas or Corgi registered
personnel.
NOTE: A service must NOT be
attempted if a CO/CO2
1
analyser is NOT available.
To ensure the continued efficient operation
of the appliance it must be checked at regular
intervals.
The frequency of servicing will depend upon
the particular installation conditions and usage
however, an annual service is recommended.
The extent of the service required by the
appliance is determined by the operating
condition of the appliance when tested by
fully qualified engineers.
The service interval record sheet at the rear
of these instructions must be completed
after each service.
2
Inspection
1
Check that the terminal and the terminal
guard, if fitted, are clear and undamaged.
If the appliance is in a compartment or
2
cupboard check that the specified service
space around the appliance is clear.
Check all the joints and connections in the
3
system and remake any that show signs of
leakage. Refill and re-pressurise if
applicable as described in Commissioning.
Operate the appliance and take note of any
irregularities.
Refer to Fault Finding for rectification
procedures.
3
INSPECTION AND SERVICE
37

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Greenstar 30si

Table of Contents