CAUTION: TURN OFF THE GAS SUPPLY AND ISOLATE THE MAINS
S U P P LI E S B E FOR E STARTI NG ANY WOR K AN D OB S E RVE ALL
RELEVANT SAFETY PRECAUTIONS.
IMPORTANT: AFTER REPLACEMENT OF ANY COMPONENTS ALWAYS
CHECK FOR GAS SOUNDNESS WHERE RELEVANT AND CARRY OUT
FUNCTIONAL CHECKS AS DESCRIBED IN COMMISSIONING.
ANY O -R I NG OR GAS KET THAT APPEARS DAMAG E D M UST B E
REPLACED.
32

INSPECTION AND SERVICE

INSPECTION AND SERVICE
I M P ORTANT: Any service work
must be carried out by competent
registered engineers such as
British Gas or Corgi registered
personnel.
NOTE: A service must NOT be
1
• To ensure the continued efficient operation
of the appliance it must be checked at
regular intervals.
• The frequency of servicing will depend upon
the particular installation conditions and
usage however, an annual service is
recommended .
• The extent of the service required by the
appliance is determined by the operating
condition of the appliance when tested by
fully qualified engineers.
• The service interval record sheet at the rear
2
of these instructions must be completed
after each service.
Inspection
1
Check that the terminal and the terminal
guard, if fitted, are clear and undamaged.
2
If the appliance is in a compartment or
cupboard check that the specified service
space around the appliance is clear. Refer to
page 11 for information.
Check all the joints and connections in the
3
system and remake any that show signs of
leakage. Refill and re-pressurise if
applicable as described in Commissioning.
Operate the appliance and take note of any
irregularities.
Refer to Fault Finding for rectification
procedures.
3
INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR Ri
attempted if a CO/CO2
analyser is NOT available.