3.2

Error Code Cause and Remedy

These errors are recoverable by following the message indicated on the LCD or following the
items indicated in User Check.
■ Error code 1E
Drum End Soon

The drum unit reached its life and requires replacement.

<User Check>
• Replace the drum unit with a new one.
■ Error code 1F
Too Many Trays
Two or more optional trays are installed.
<User Check>
• Install one optional tray.
Step
1
Connector: 54702-1219 failure
2
Main PCB failure
■ Error code 24
Print Unable 24
Turn the power off and then back on again.
Internal temperature sensor failure
Step
Harness connection failure of
1

internal temperature sensor

2
Internal temperature sensor failure Replace the internal temperature sensor.
3
Main PCB failure
Cause
Cause
3-12
Remedy
Replace the connector: 54702-1219.
Replace the main PCB ASSY.
Remedy
Check the harness connection of the
internal temperature sensor and reconnect
it.
Replace the main PCB ASSY.