5.9 Heating element

5.9.1

General characteristics

The heating element that heats the washing water is encapsulated, i.e. inserted into a watertight stainless
steel tubular casing.
1. Heating element
(1950W)
2. NTC sensor
5.9.1.1
Seal
The seal between the tub and the heating element is provided by a seal which expands against the nut.
1. Fixed flange
2. Washer
3. Moving flange
4. Nut
5. Heating element terminals
6. NTC Sensor
5.9.2

Electrical symbol

5.9.3

Checking for efficiency

DOES NOT HEAT:
-
check that the heating element is not broken: measure the resistance across the two terminals.
INTERVENTION OF ELECTRICAL SAFETY CUT-OUTS:
-
use an ohmmeter to check that the heating element is not connected to mass and check for current
leakage (40 MΩ)
WATER LEAKS:
check that the seal is correctly positioned and fitted.
-
VIBRATION OR METALLIC NOISE WHEN THE DRUM ROTATES:
-
check that the heating element is correctly positioned inside the tub. If worn, replace the heating
element.
2005.11 dmm