Electrolux Washer Service Manual page 59

Washing machines & washer-dryers with ewm2000evo electronic control
Table of Contents

Advertisement

Alarm
Description
Fault in NTC sensor on drying duct (voltage out
E73
of range = short-circuit, open circuit)
NTC sensor for wash cycle improperly
E74
positioned
E82
Error in selector reset position
E83
Error in reading selector
"Sensing" circuit on circulation pump triac
E84
faulty
(input signal to microprocessor always 0V or 5V)
Circulation pump faulty
E85
(incongruency between status of "sensing"
circuit on circulation pump and status of TRIAC)
Communication incongruence between main
E91
PCB- display board
(versions not compatible)
Communication incongruence between main
E92
PCB- display board
(versions not compatible)
E93
Incorrect configuration of appliance
E94
Incorrect configuration of washing cycle
Communication error between microprocessor
E95
and EEPROM
Incongruence between programme selector and
E97
cycle configuration
EB1
Frequency of appliance incorrect
EB2
Voltage too high
EB3
Voltage too low
Solenoid valve inoperative but flow meter
EC1
operating
EC2
Signal from turbidity sensor out of limits
EC3
Signal from weight sensor out of limits
Drain filter blocked
EF1
(too long drain phase)
Overdosing of detergent
EF2
(too much foam during drain phases)
EF3
Control water intervention
Low pressure of water fill, no signal of flow meter
EF4
and solenoid open
E00
No alarm
SOI/DT 2005-01 dmm
Possible fault
Drying NTC sensor (duct) defective; wiring defective; main circuit
board defective.
NTC sensor improperly positioned; Defective NTC sensor; Wiring
defective; Main board defective.
PCB faulty (Wrong configuration data). Selector, wiring
PCB faulty (Wrong configuration data). Selector, wiring
PCB
Circulation pump;
wiring;
main PCB
Wiring faulty; Faulty control/display board
Main PCB faulty.
Wrong control/display board;
Wrong PCB (do not correspond to the model).
Incorrect configuration data; PCB faulty.
Incorrect configuration data; PCB faulty.
PCB faulty.
Faulty PCB (Wrong configuration data).
Power supply problems (incorrect / disturbance); PCB faulty.
Power supply problems (incorrect / disturbance); PCB faulty.
Power supply problems (incorrect / disturbance); PCB faulty.
Main board defective, Solenoid valve defective
Turbidity sensor defective, Main board defective, Wiring defective
Weight sensor defective, Main board defective, Wiring defective
Drain tube blocked/kinked/too high;
Drain filter dirty/blocked.
Excessive detergent dosing; drain tube kinked/blocked;
Drain filter dirty/blocked.
Water leakage on the base; faulty water control device.
Tap closed, low water fill pressure
---
59/65
Action/machine status
Heating is skipped
Heating is skipped
---
Cycle cancelled
Drain, cycle blocked (door open)
Drain, cycle blocked (door open)
Cycle interrupted
Cycle interrupted
Cycle interrupted
Cycle interrupted
Cycle interrupted
Cycle interrupted
Cycle interrupted
Cycle interrupted
Cycle interrupted
Cycle stops with door locked (after 5
attempts).
---
---
Warning displayed at the end of cycle
(specific LED)
(specific LED)
Water drain and cycle blocked
---
---
Reset
Start
Start
OFF/reset
---
OFF/reset
OFF/reset
---
---
OFF/reset
OFF/reset
OFF/reset
OFF/reset
---
---
---
OFF/reset
Start/reset
Start/reset
---
---
OFF/reset
Reset
---
599 36 82-56