Choosing the Installation Location
Indoor Unit
Where airflow is not blocked
Where cool air can be distributed throughout the room
Install the refrigerant piping length and the height
difference of both indoor and outdoor units as
indicated in the installation diagram
Wall that prevents vibration and is strong enough to hold the
product weight
Out of the direct sunlight
3.3ft or more away from the TV or radio
(to prevent the screen from being distorted or noise from being
generated)
As far away as possible from fluorescent and incandescent lights
(so that the remote control can be operated well)
A place where the air filter can be replaced easily
CAUTION
Avoid the following places to prevent malfunction of the unit
- Where there is machine oil
- Where sulfide gas exists
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.
Wrap the refrigerant pipes and the drain
hose with the absorbent pad and vinyl
tape. Refer to page 15 for further details.
11.8 inch
minimum
23.6 inch
minimum
Outdoor Unit
Where it is not exposed to strong wind
Well ventilated and dustless places
Out of the direct sunlight and rain
Where neighbors are not annoyed by operation sound or hot air
Solid wall or support that prevents vibration and is strong
enough to hold the product weight
Where there is no risk of flammable gas leakage
When installing the unit at a high place be sure to fix the unit
legs
9.9ft or more away from the TV or radio (to prevent the screen
from being distorted or noise from being generated)
Install the unit horizontally
- Salty environment such as the seaside areas
- Other special atmosphere areas
4.9 inch
or more
CAUTION:
9.9ft as minimum pipe length.
It will reduce noise and vibration
23.6 inch
minimum
'L' meters maximum
total pipe length
A
B
11.8 inch
minimum
Make at least one round:
It will reduce noise and vibration
The appearance of the unit may be different from the diagram depending on the model.
11.8 inch or more
You can select the direction
of draining. (left or right)
'H' meters maximum
total pipe Height
C
D
Main power switch
P
I
REPARING FOR
NSTALLATION
4.9 inch
or more
Model
L(ft) H(ft)
50 98.4
49.2
80 229.7 49.2
5