Choosing the Installation Location

Indoor Unit
 Where airflow is not blocked
 Where cool air can be distributed throughout the room
 Install the refrigerant piping length and the height
difference of both indoor and outdoor units as
indicated in the installation diagram
 Wall that prevents vibration and is strong enough to hold the
product weight
 Out of the direct sunlight
 1m or more away from the TV or radio
(to prevent the screen from being distorted or noise from being
generated)
 As far away as possible from fluorescent and incandescent lights
(so that the remote control can be operated well)
 A place where the air filter can be replaced easily
CAUTION
Avoid the following places to prevent malfunction of the unit
- Where there is machine oil
- Where sulfide gas exists
Observe the clearances and maximum lengths as seen in the picture below when installing the air conditioner.
Wrap the refrigerant pipes and the drain
hose with the absorbent pad and vinyl
tape. Refer to page 18 for further details.
300 mm
minimum
600 mm
minimum
The appearance of the unit may be different from the diagram depending on the model.
08'FORTE_IM_28592A_E.indd 5
Outdoor Unit
 Where it is not exposed to strong wind
 Well ventilated and dustless places
 Out of the direct sunlight and rain
 Where neighbors are not annoyed by operation sound or hot air
 Solid wall or support that prevents vibration and is strong
enough to hold the product weight
 Where there is no risk of flammable gas leakage
 When installing the unit at a high place be sure to fix the unit
legs
 3m or more away from the TV or radio (to prevent the screen
from being distorted or noise from being generated)
 Install the unit horizontally
- Salty environment such as the seaside areas
- Other special atmosphere areas
125 mm
or more
You can select the direction
of draining. (left or right)
CAUTION:
'L' m as maximum pipe length and 3 m as
minimum pipe length (It will reduce noise
and vibration)
600 mm
minimum
'L' meters maximum
total pipe length
300 mm
minimum
Make at least one round:
It will reduce noise and vibration
P
REPARING FOR
300 mm or more
125 mm
or more
'H' meters maximum
total pipe Height
Model
09
12
18
24
I
NSTALLATION
L
H
15
7
15
7
15
8
20
8
5
E-
2007-12-14 9:54:25