Connecting The Assembly Cable - Samsung MH026FNCA Installation Manual

Mh***fnca series free joint multi air conditioner
Hide thumbs Also See for MH026FNCA:
Table of Contents

Advertisement

I
A
NSTALLING THE
IR CONDTIONER

Connecting the Assembly Cable

Indoor unit
1(L)
2(N)
F1
1 2
Earth
terminal
1 2
Outdoor
Earth
unit
terminal
1(L) 2(N)
 S crews on terminal block must
not be unscrewed with the
torque less than 0.87 ft•lb.
12
E-
When you install the unit, make first refrigerant connections and then elec-
trical connections.Connect the air conditioner to grounding system before
performing the electrical connection.If unit is uninstalled first disconnect
electrical cables, then refrigerant connections.
1
Extend the assembly cable if necessary.
2
Open the front grille by pulling on the tabs on the lower right and left sides of
the indoor unit.
3
Remove the screw securing the connector cover.
4
Pass the assembly cable through the rear of the indoor unit and connect
the assembly cable to terminals as seen in the picture.
 Each wire is labeled with the corresponding terminal number.
F2
5
Pass the other end of the cable through the 2.56inch hole in the wall.
F1 F2
6
Close the connector cover, tightening the screw carefully.
7
Close the front grille.
F1 F2
F1 F2
8
Remove the terminal board cover on the side of the outdoor unit.
9
Connect the cables to the terminals as seen in the picture.
 Each wire is labeled with the corresponding terminal number.
10
Connect the grounding conductor to the grounding terminals.
11
Close the terminal board cover, tightening the screw carefully.
12
Connect the power cable to the indoor unit.
13
For further details on how to plug the other end of the assembly cable into
the outdoor unit, refer to installation manual of the outdoor unit.
In Russia and Europe, consult with the supply authority to determine
the supply system impedance before installation.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mh035fncaMh052fnca

Table of Contents