Unit Nomenclature; Model Number Description - Trane YSC060 Installation Operation & Maintenance

Packaged gas/electric
Table of Contents

Advertisement

Unit Nomenclature

Digit 1 - Product Type
Y = Packaged Gas/Elect
Digit 2 - Unit Efficiency Level
S = Standard
Digit 3 - Airflow Configuration
C = Convertible
Digit 4, 5, 6 - Cooling Capacity
060 = 5 Ton
( 17.6 KW )
072 = 6 Ton
( 21.1 KW )
090 = 7 1/2 Ton ( 26.4 KW )
102 = 8 1/2 Ton ( 29.9 KW )
120 = 10 Ton
( 35.1 KW )
Digit 7 - Major Design Sequence
A
Digit 8 - Electrical Characteristics
D = 380-415/50/3
Digit 9 - Unit Control
R = Relia Tel
Digit 10 - Heat Capacity
H = Gas Heat - High
L = Gas Heat - Low
Digit 11 - Minor Design Sequence
*
Digit 12, 13 - Service Digit Sequence
**
Digit 14 - Factory Installed Options
-Fresh Air Section
0 = No Fresh Air
A = Manual OA, 0 - 25%
B = Motorized OA, 0 - 50%
C = Economizer Dry Bulb
D = Economizer with
Barometric Relief
E = Economizer, Reference Enthalpy
F = Economizer, Reference Enthalpy,
with Barometric Relief
G = Economizer Comparative Enthalpy
H = Economizer, Comparative Enthalpy,
with Barometric Relief
4

Model Number Description

Digit 15 - Factory Installed Options
-Supply Fan
0 = Standard Drive
1 = Oversize Motor
Digit 16 - Factory Installed Options
-Hinged Service Access
0 = Standard Panels
A = Hinged Service Panels
Digit 17 - Factory Installed Options
-Condenser Coil Protection
0 = Standard
1= Hail Guard
2 = Epoxy Coated Condenser Coil
3 = Epoxy Coated Condenser Coil and
Hail Guard
4 = CompleteCoat Condenser Coil
5 = CompleteCoat Condenser Coil and
Hail Guard
Digit 18 - Factory Installed Options
-Through The Base
0 = Without Through The Base
Connection
Digit 19 - Factory Installed Options
-Disconnect Switch/Circuit Breaker
0 = Without Disconnect Switch/Circuit
Breaker
3 = With Phase Monitor
Digit 20 - Factory Installed Options
-Convenience Outlet
0 = Without Convenience Outlet
Digit 21 - Factory Installed Options
-Communications
0 = Without Communications Options
1 = Trane Communications Interface
2 = LoneTalk Communications
Interface
Digit 22 - Factory Installed Options
-Refrigeration System
0 = Without Refrigeration System Op-
tion
Digit 23 - Factory Installed Options
-Refrigeration Controls
0 = Without Refrigeration Controls
Digit 24 - Factory Installed Options
-Smoke Detector
0 = Without Smoke Detector
Digit 25 - Factory Installed Options
-System Monitoring Controls
0 = Without Monitoring Controls
1 = Clogged Filter Switch
2 = Fan Failure Switch
3 = Discharge Air Sensing Tube
4 = Clogged Filter Switch and Fan
Failure Switch
5 = Clogged Filter Switch and
Discharge Air Sensing Tube
6 = Fan Failure Switch and
Discharge Air Sensing Tube
7 = Clogged Filter Switch, Fan Failure
Switch and
Discharge Air Sensing Tube
RT-SVX31A-EN