Wiring Diagram - Napoleon GS60-N Installation And Operating Instructions Manual

Natural gas, propane gas
Table of Contents

Advertisement

8.0 WIRING DIAGRAM

This appliance comes equipped with a battery back-up. If this backup is used install four AA batteries (not
supplied) into the holder and connect to the wire harness. Place near the IPI board. Connect the battery holder
to the wire harness before using the appliance. Place near the IPI board. (Batteries not included). If backup is
used, it must be connected to the 6 volt battery pack supplied.
FIGURE 8.0
DC BACK-UP
-
+
TRANSFORMER
+
-
DC SUPPLY
ACS/IPI
SWITCH
ON / OFF
SWITCH
IPI / CPI
ON / OFF
DISCONNECT THESE
CONNECTORS TO THE
ON/OFF SWITCH AND
CONNECT TO
OPTIONAL WALL /
THERMOSTAT SWITCH
AND / OR SPILL SWITCH
TO "B" VENT ADAPTOR
VALVE
GROUND
EYELET
GROUND
GREEN
ORANGE
VALVE
ELECTRONIC
IPI BOARD
DFC
W415-0788 / A / 09.22.09
39

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs60pGds60p

Table of Contents