Cabinet And Duct Dimensions; Electrical And Performance Data - Coleman FC9V Series Technical Manual

Coleman gas-fired condensing / high efficiency two stage variable upflow furnaces
Table of Contents

Advertisement

260614-CTG-C-0407
CONDENSATE
DRAIN 7/8" K.O.
OPTIONAL RETURN AIR
CUT-OUT (either side)
FOR USE WITH
EXTERNAL FILTER
FRAME
7/8

CABINET AND DUCT DIMENSIONS

Nominal
Models
CFM
FC9V040A12UP11
1200
FC9V060B12UP12
1200
FC9V080B12UP11
1200
FC9V080C16UP12
1600
FC9V100C20UP12
2000
FC9V120D20UP12
2000

ELECTRICAL AND PERFORMANCE DATA

Input
High/Low
Models
MBH
FC9V040A12UP11
40/26
FC9V060B12UP12
60/39
FC9V080B12UP11
80/52
FC9V080C16UP12
80/52
FC9V100C20UP12
100/65
FC9V120D20UP12
120/78
Input
High/Low
Models
MBH
FC9V040A12UP11
40/26
FC9V060B12UP12
60/39
FC9V080B12UP11
80/52
FC9V080C16UP12
80/52
FC9V100C20UP12
100/65
FC9V120D20UP12
120/78
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
* Wire size and overcurrent protection must comply with the National Electric Code.
NOTES:
1. For altitudes above 2000 ft. reduce capacity 4% for each 1000 ft. above sea level.
2. Wire size based on copper conductors, 60°C, 3% voltage drop.
3. Continuous return air temperature must not be below 55°F.
4. All filters must be high velocity cleanable type.
2
1-1/2" GAS
PIPE ENTRY
7/8" JUNCTION
BOX HOLE
T-STAT WIRING
7/8" K.O.
13-7/8
23-3/4
7/8
30-1/8
LEFT SIDE
26-3/4
BOTTOM IMAGE
RETURN END
Cabinet
Size
A
B
B
C
C
D
Output
Nominal
High/Low
Airflow*
MBH
CFM
38/24
1200
56/36
1200
75/49
1200
75/49
1600
93/60
2000
112/73
2000
Max. Outlet
Blower
Air Temp.
°F
HP
Amps
165
1/2
7.7
170
1/2
7.7
175
1/2
7.7
175
3/4
9.6
175
1
12.8
170
1
12.8
A
40
FRONT
1-1/2
24-3/8
1-1/4
20
D
C
2
24-17/16
TOP IMAGE
SUPPLY END
Cabinet Dimension
A (in.)
B (in.)
14-1/2
13-1/2
17-1/2
16-1/4
17-1/2
16-1/4
21
19-3/4
21
19-3/4
24-1/2
23-1/4
Cabinet
Total Unit
Width
In.
Amps
14-1/2
9
17-1/2
9
17-1/2
9
21
12
21
14
24-1/2
14
Blower
Max.
Min. Wire Size
Size
Over-
(awg) @ 75 ft.
current
In.
Protect
11 x 8
20
11 x 8
20
11 x 8
20
11 x 10
20
11 x 11
20
11 x 11
20
1-1/2" GAS
PIPE ENTRY
7/8" JUNCTION
BOX HOLE
T-STAT WIRING
7/8" K.O.
CONDENSATE
DRAIN 7/8" K.O.
RIGHT SIDE
5/8
5/8
B
C (in.)
11-1/2
14-1/2
14-1/2
18
18
21-1/2
High Fire
AFUE
Air Temp. Rise
%
°F
94.0
35 - 65
95.0
40 - 70
92.5
45 - 75
95.0
45 - 75
95.0
45 - 75
95.0
40 - 70
Operating
Wgt.
One Way
Lbs.
14
121
14
135
14
142
14
157
12
164
12
180
Unitary Products Group
D (in.)
6-1/4
8-1/2
8-1/2
8-7/8
8-7/8
10-5/8
Low Fire
Air Temp. Rise
°F
35 - 65
20 - 50
45 - 75
20 - 50
20 - 50
20 - 50