LEFT SIDE

Combustion Air Inlet
Condensate Drain
(Downflow)
Vent Outlet
28.5"
29.5"
.56"
23.8"
Combustion
B
Air Inlet
.56"
.56"
20"
SUPPLY END
Cabinet & Duct Dimensions
BTUH (kW)
Input
TG9S040A08MP11
TG9S060A10MP11
TG9S060B12MP11
TG9S080B12MP11
TG9S080C16MP11
TG9S080C22MP11
TG9S100C16MP11
TG9S100C20MP11
TG9S120D16MP11
TG9S120D20MP11
TG9S130D20MP11
Ratings & Physical / Electrical Data
Input
TG9S040A08MP11
TG9S060A10MP11
TG9S060B12MP11
TG9S080B12MP11
TG9S080C16MP11
TG9S080C22MP11
TG9S100C16MP11
TG9S100C20MP11
TG9S120D16MP11
TG9S120D20MP11
TG9S130D20MP11
Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.
2
Gas Pipe
Entry
Electrical
Entry
Condensate
Drain
Thermostat
Wiring
3"
Vent
Outlet
C
Nominal
Cabinet
3
Size
CFM (m
/min)
800
1000
1200
1200
1600
2200
1600
2000
1600
2000
2000
Nominal
Output
Total Unit
Airflow
Amps
MBH
CFM
38
800
8.0
57
1000
10.0
57
1200
10.0
76
1200
10.0
76
1600
11.5
76
2200
17.0
95
1600
11.5
95
2000
17.0
114
1600
11.5
114
2000
17.0
123.5
2000
17.0
FRONT
Gas Pipe
Entry
Electrical
Entry
33
Condensate
Drain
Thermostat
Wiring
A
Cabinet Dimensions (Inches)
A
A
14 1/2
13 3/8
A
14 1/2
13 3/8
B
17 1/2
16 3/8
B
17 1/2
16 3/8
C
21
19 7/8
C
21
19 7/8
C
21
19 7/8
C
21
19 7/8
D
24 1/2
23 3/8
D
24 1/2
23 3/8
D
24 1/2
23 3/8
Air Temp.
Rise
AFUE
°F
95.5
30-60
95.5
30-60
95.5
30-60
95.5
35-65
95.5
35-65
95.5
35-65
95.5
35-65
95.5
35-65
95.5
40-70
95.5
35-65
95.5
45-75

RIGHT SIDE

Combustion Air Inlet
Condensate Drain
(Downflow)
Vent Outlet
23"
Optional Return Air
Cutout (Either side)
24.25"
RETURN END
Operating Weights
B
C
11 3/4
11 3/4
13 1/4
14 3/4
16 1/2
16 1/2
18 1/4
18 1/4
21 3/4
21 3/4
No Hole
Max
Min. wire Size
Over-Current
(awg) @ 75 ft
Protect
one way
15
14
15
14
15
14
15
14
15
14
20
12
15
14
20
12
15
14
20
12
20
12
Johnson Controls Unitary Products
14"
1"
1.5"
B
Approximate
Lbs
113
118
122
126
136
139
142
145
153
156
160
Max. Outlet
Air Temp
°F
155
155
160
165
155
155
165
155
170
160
165

Hide quick links:

Advertisement

loading

This manual is also suitable for:

Tg9s040a08mp11Tg9s060a10mp11Tg9s060b12mp11Tg9s080b12mp11Tg9s080c16mp11Tg9s080c22mp11 ... Show all