INSTALLATION MANUAL
DOWNFLOW/UPFLOW
ELECTRIC FURNACE
MODELS: EB
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
UNIT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
DOWNFLOW FURNACE INSTALLATION . . . . . . . . . . . . . . . . . . . . . 3
Furnace Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Upflow Closet Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Duct Connector Depth (7990 Series) . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Duct Connector Dimensions (7990 Series) . . . . . . . . . . . . . . . . . . . . . 4
Recommended Floor Cut-out (7990 Series) . . . . . . . . . . . . . . . . . . . . 4
Duct Connector Screw Attachment (7990 Series) . . . . . . . . . . . . . . . . 4
Duct Connector Tab Attachment (7990 Series) . . . . . . . . . . . . . . . . . . 4
Duct System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Installation of Furnace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Hanger Angle Attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Duct Connector for Electric Furnaces . . . . . . . . . . . . . . . . . . . . . . . . . 3
Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SECTION I: GENERAL
The following list includes important facts and information regarding the
EB furnace and its packaging inclusions:
1.
Furnace is rated at 240 volts, 60 Hz, single phase.
2.
Heating and Cooling thermostat is packed with furnace.
3.
Filters are furnished with each model, and are the same for all
models - 16 x 20 x 1.
4.
Furnace size is the same for all models. See Figure 1.
5.
Four-wire thermostat operation for heating and cooling.
6.
Coil cavity built into furnace.
7.
All furnaces are equipped with an air conditioner blower and is A/C
or Heat Pump ready.
8.
Holding strap furnished on top rear of furnace.
9.
This furnace is designed for downflow application; however, it may
be converted to an upflow application. (See Page 6 for upflow con-
version instruction.)
10. This furnace must not be operated without the front panel installed.
NOTE: This furnace and its components listed on the A/C and Heat
Pump equipment sticker were listed in combination as a system by
Underwriter's Laboratories for the United States and Canada.
LIST OF SECTIONS
THERMOSTAT INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
OPTIONAL AIR CONDITIONING ACCESSORIES . . . . . . . . . . . . . . .9
WIRING DIAGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
LIST OF FIGURES
Blower Bracket and Duct Flange Attachment . . . . . . . . . . . . . . . . . . . .6
Control Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Field Wiring Shield . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Thermostat Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Thermostat Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
EB10C Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
EB12C Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
EB15C Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
EB17C Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
EB20C Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
EB23C Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
LIST OF TABLES
EB Series Blower Performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Thermostat
Wiring
Entry
Field
Wiring
Entry
J
H
FIGURE 1: Furnace Dimensions
"
19-5/8
Sub-Base, if
Used, Adds 7/8"
More to Total
51-5/8"
Height and
3/8" to width.
N
M
L
K
OPTIONAL BOTTOM FIELD
WIRING ENTRY
E
A
F G
B
D
C
ISO 9001
Certified Quality
Management System
A
1-7/8"
2-5/8"
B
C
3-1/2"
D
1"
E
5-1/16"
5-1/2"
F
G
5-13/16"
H
1"
J
1-3/4"
K
7-13/16"
L
8-5/8"
9-7/16"
M
N
16-1/2"
266180-BIM-B-0209

Advertisement

Table of Contents
loading

Summary of Contents for Coleman EB23C

  • Page 1: Table Of Contents

    EB20C Wiring Diagram ........12 EB23C Wiring Diagram ........12 LIST OF TABLES Duct Connector for Electric Furnaces .
  • Page 2: Safety

    266180-BIM-B-0209 SECTION II: SAFETY Provide clearances from combustible materials as listed under Clearances to Combustibles. This is a safety alert symbol. When you see this symbol on Provide clearances for servicing ensuring that service access is labels or in manuals, be alert to the potential for personal allowed for electric furnace elements and blower.
  • Page 3: Downflow Furnace Installation

    266180-BIM-B-0209 SECTION IV: DOWNFLOW FURNACE RETURN AIR INSTALLATION In order for the furnace to work properly, a closet or alcove must have a certain total free area opening for return air. 7900 SERIES DUCT CONNECTOR For Heating Only Furnace We have designed our duct connector to eliminate a sub-base require- Minimum 200 in (1290 cm ) free area opening.
  • Page 4: Duct Connector Dimensions (7990 Series)

    266180-BIM-B-0209 INSTALLATION OF SCREW ATTACHMENT DUCT CONNECTOR (7990 SERIES) SCREW ATTACHMENT 18-3/4 Make floor cut out as shown in Figure 5. 2-3/8 2-3/8 Determine the depth of the floor cavity from the surface of the floor Chart to the top of the supply air duct and select the appropriate duct connector from the chart.
  • Page 5: Duct System Configuration

    266180-BIM-B-0209 INSTALLATION OF THE FURNACE Determine which of the four positions the duct connector best cen- ters over the supply duct and insert it through the floor cutout. Remove the front panels and set the furnace onto the duct con- Mark cut-out location on the supply duct and remove the duct con- nector.
  • Page 6: Wiring Requirements

    IMPORTANT: All installation on field wiring must be rated at 60ºC or (Upflow Furnace) higher. Models for EB23C, EB20C, EB17C and EB15C may be connected to a single or dual branch circuit. These units are shipped from the factory set up for dual power supply connections.
  • Page 7: Control Box

    1021 High - with A-Coil in place CFM (STD. Air) 1573 1534 1490 1435 1369 1309 1237 1135 1019 TABLE 4: Electrical Data MODEL NUMBER EB23C EB20C EB17C EB15C EB12C EB10C 240 VAC 77,000 67,000 56,000 51,000 39,000 34,000 D.O.E.
  • Page 8: Thermostat Installation

    266180-BIM-B-0209 closely regulate average room air, preferably, where there is air move- ment back to furnace. Care should be used to locate thermostat away from hot air discharge openings, lights, etc. Locating height of thermo- stat is important. Thermostat should be located 52” to 66” (132 - 167.6 For personal safety be sure to turn the electrical power OFF at the cm) above the floor.
  • Page 9: Optional Air Conditioning Accessories

    266180-BIM-B-0209 SECTION VI: OPTIONAL AIR HIGH PERFORMANCE BLOWER ACCESSORY PACK- CONDITIONING ACCESSORIES Failure to install this insulation and coil shelf kit could result in All areas around the line sets, drain hoses and other openings in damage to equipment and/or personal injury. Liability and war- the coil shelf should be sealed air tight.
  • Page 10: Wiring Diagrams

    266180-BIM-B-0209 SECTION VII: WIRING DIAGRAMS CAPACITOR BLEND AIR CONTROL BOX 4-SPEED BLOWER MOTOR EB SERIES FURNACES HEAT/COOL T’STAT COND. UNIT CONTACTOR 2 SPADE (INSUL.) TERMINALS USED WHEN CHANGING SPEEDS TRANSFORMER BLOWER RELAY LINE FUSE LOAD CIRCUIT #1 BREAKER 240 VAC. SEQUENCER 60 Hz 1 PHASE...
  • Page 11: Eb15C Wiring Diagram

    266180-BIM-B-0209 CAPACITOR BLEND AIR 4-SPEED BLOWER MOTOR CONTROL BOX EB SERIES FURNACES HEAT/COOL T’STAT MODEL: EB15C COND. UNIT CONTACTOR CIRCUIT #1 SINGLE BRANCH BREAKER CIRCUIT SERVICE 2 SPADE (INSUL.) TERMINALS USED WHEN CHANGING SPEEDS TRANSFORMER 240 VAC. LINE 60 Hz FUSE 1 PHASE LOAD...
  • Page 12: Eb20C Wiring Diagram

    (OR CB) - AMPS APPROVED FOR CU CONDUCTORS ONLY. ‡ REQUIRES JUMPER BARS (P/N 3500-378/*) FIGURE 21: EB23C Wiring Diagram Subject to change without notice. Printed in U.S.A. 266180-BIM-B-0209 Copyright © 2009 by Johnson Controls, Inc. All rights reserved. Supersedes: 266180-BIM-A-0607...

This manual is also suitable for:

Eb17cEb20cEb15cEb12cEb10c

Table of Contents