Coleman FC9V Series Technical Manual

Coleman FC9V Series Technical Manual

Coleman gas-fired condensing / high efficiency two stage variable upflow furnaces

Advertisement

TECHNICAL GUIDE
Echelon
MODELS: FC9V*UP
GAS-FIRED
CONDENSING / HIGH EFFICIENCY
TWO STAGE VARIABLE
UPFLOW FURNACES
UP TO 95% AFUE
NATURAL GAS
40 - 120 MBH INPUT
EFFICIENCY
RATING
CERTIFIED
Due to continuous product improvement, specifications
are subject to change without notice.
Visit us on the web at www.york.com for the most
up-to-date technical information.
Additional rating information can be found at
www.gamanet.org.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
DESCRIPTION
These Category IV, highly efficient, compact, condensing
type furnaces are designed for residential and commercial
installations in a basement, closet, alcove, recreation room or
garage where the ambient temperature is above 32°F, or
higher. They may be either side wall or thru-roof vented using
approved plastic type combustion air and vent piping. All
units are factory assembled, wired and tested to assure
dependable and economical installation and operation.
WARRANTY
Lifetime limited warranty on both heat exchangers to the orig-
inal purchaser; a 20-year limited warranty from original instal-
lation date to subsequent purchaser.
10-year warranty on the heat exchanger in commercial appli-
cations.
5-year limited parts warranty.
FEATURES
• Two stage heating operation includes:
• Provides increased comfort level & very quiet unit opera-
• Adjustable delay timer allows two stage operation with sin-
• Compact, easy to install, ideal height 40" cabinet
• Blower-off delay for cooling SEER improvement.
• Easy to connect power/control wiring.
• Built-in, high level self diagnostics with fault code display.
• Low unit amp requirement for easy replacement applica-
• Integrated control module for reliable, economical opera-
• May be installed as either two-pipe (sealed combustion) or
• Top intake & vent connection allows installation in narrow
• Electronic Hot Surface Ignition saves fuel cost with
• Induced combustion system with inshot main burners for
• No special vent termination kit required.
• 100% shut off main gas valve for extra safety.
• 24V, 40 VA control transformer and blower relay supplied
• Hi-tech tubular aluminized steel primary heat exchanger.
• Secondary (condensing) heat exchanger of 29-4C high-
ISO 9001
Certified Quality
• Timed on, adjustable off blower capability for maximum
Management System
• Solid removable bottom panel allows easy application.
• Easy access from front of unit for cleaning, maintenance or
• Protection from intake, exhaust or condensate blockage.
• Insulated blower compartment for quiet operation.
• EcoTrak comfort system allows dealer to customize com-
- Two stage gas valve
- Two stage inducer operation
- Variable speed ECM blower operation
tion
gle stage thermostat
tion.
tion.
single pipe vent (using indoor combustion air)
locations.
increased dependability and reliability.
quiet, efficient operation.
for add-on cooling.
grade stainless steel.
comfort.
service.
fort settings based on regional location.
260614-CTG-C-0407

Advertisement

Table of Contents
loading

Summary of Contents for Coleman FC9V Series

  • Page 1 260614-CTG-C-0407 DESCRIPTION These Category IV, highly efficient, compact, condensing type furnaces are designed for residential and commercial installations in a basement, closet, alcove, recreation room or garage where the ambient temperature is above 32°F, or higher. They may be either side wall or thru-roof vented using approved plastic type combustion air and vent piping.
  • Page 2: Cabinet And Duct Dimensions

    260614-CTG-C-0407 1-1/2” GAS PIPE ENTRY 1-1/2” GAS 7/8” JUNCTION PIPE ENTRY BOX HOLE T-STAT WIRING 7/8” JUNCTION 7/8” K.O. BOX HOLE CONDENSATE DRAIN 7/8” K.O. OPTIONAL RETURN AIR T-STAT WIRING CUT-OUT (either side) 13-7/8 7/8” K.O. FOR USE WITH EXTERNAL FILTER CONDENSATE FRAME DRAIN 7/8”...
  • Page 3: Air Flow Data

    260614-CTG-C-0407 AIR FLOW DATA HIGH / LOW SPEED COOLING AND HEAT PUMP CFM FC9V040A12UP11 FC9V060B12UP12 Jumper Settings High High COOL Tap ADJ Tap* 1340 1330 1205 1130 1255 1220 1150 1040 1170 1120 1025 1045 FC9V080B12UP11 FC9V080C16UP12 JUMPER SETTINGS High High COOL Tap ADJ Tap*...
  • Page 4: Filter Sizes

    260614-CTG-C-0407 FILTER PERFORMANCE APPLYING FILTER PRESSURE DROP TO DETERMINE SYSTEM AIRFLOW The airflow capacity data published in the “Blower Perfor- mance” table listed above represents blower performance To determine the approximate airflow of the unit with a filter in WITHOUT filters. To determine the approximate blower per- place, follow the steps below: formance of the system, apply the filter drop value for the fil- Select the filter type.
  • Page 5 260614-CTG-C-0407 For additional connection diagrams for all UPG equipment refer to “Low Voltage System Wiring” document available online at www.upgnet.com in the Product Catalog Section. Thermostat Chart - AC Unitary Products Group...
  • Page 6 260614-CTG-C-0407 Thermostat Chart - HP Unitary Products Group...
  • Page 7 260614-CTG-C-0407 ACCESSORIES SIDE RETURN FILTER RACK - 1SR0302 - All Models PROPANE (LP) CONVERSION KIT - 1SR0200 - All Models 1NP0347 - All units This accessory conversion kit may be used to convert natural BOTTOM RETURN FILTER RACK - gas (N) units for propane (LP) operation. Conversions must 1BR0114 or 1BR0214 - For 14-1/2”...
  • Page 8 NOTES Subject to change without notice. Printed in U.S.A. 260614-CTG-C-0407 Copyright © by York International Corp. 2007. All rights reserved. Supersedes: 260614-CTG-B-0806 Unitary 5005 Norman Products York Group Drive 73069...