GE ZIC36ON Series Technical Service Manual page 43

Monogram bmnf refrigerators with electronic controls
Table of Contents

Advertisement

Unplug refrigerator.
Warm freezer thermistor to 70 ˚F.
Connect power and set controls to
37 ˚F and 0 ˚F.
Is the compressor running?
YES
Adjust setting and allow
24 hours to stabilize.
Compressor Not Running
Check for 120 VAC at
connector J7-9 orange wire to
NO
terminal J8 white wire.
Do you have 120 VAC?
YES
Direct-test the
compressor.
Did it start?
YES
Check wiring to
compressor, overload
and, relay.
– 41 –
Replace main
NO
control board.
Replace
NO
compressor.