16. Solder the suction line to the evaporator using
silfos.
Note: Mastic should be replaced on evaporator
discharge line after replacing the evaporator.
17. Solder the capillary tube to the evaporator
using silfos.
18. Install a replacement dryer.
19. Evacuate and recharge the system using
currently accepted procedures.
Auxiliary Line
A stainless steel hot gas loop is routed from the
machine compartment down the back of the unit
into the drain pan and back up to the machine
compartment. Hot refrigerant gas flows through
the gas loop to assist the evaporation of drain
water collected in the drain pan.

Refrigerant Charge

The refrigerant used in this model is type R134a.
Refer to the mini-manual or model tag for the
exact refrigerant charge quantity.