Download Print this page
Wells RW-1HD Owner's Manual

Wells RW-1HD Owner's Manual

Free standing drawer warmers with thermostatic control
Hide thumbs Also See for RW-1HD:

Advertisement

Model RW-2HD
Model RWN-2
This manual is considered to be part of the appliance and is to be given to the OWNER or
MANAGER of the restaurant, or to the person responsible for TRAINING OPERATORS of
this appliance. Additional manuals are available from your WELLS DEALER.
THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR
INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any
questions concerning installation, operation or maintenance of this equipment.
2M-303335
p/n
Rev. E
WELLS BLOOMFIELD, LLC
10 Sunnen Dr., St. Louis, MO 63143
telephone: 888-356-5362
IMPORTANT: DO NOT DISCARD THIS MANUAL
fax: 314-781-2714
www.wells-mfg.com
OWNERS MANUAL
FREE STANDING
DRAWER WARMERS
with THERMOSTATIC
EXPLODED VIEW
WIRING DIAGRAM
041
CONTROL
MODELS
RW-1HD
RW-2HD
RW-3HD
RWN-1
RWN-2
RWN-3
Includes
INSTALLATION
USE & CARE
PARTS LIST
10
M041
1004

Advertisement

loading

Summary of Contents for Wells RW-1HD

  • Page 1 Additional manuals are available from your WELLS DEALER. THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE. Contact your WELLS DEALER if you have any questions concerning installation, operation or maintenance of this equipment.
  • Page 2 The for information and other details concerning warranty. prices charged by Wells Bloomfield for its products are SERVICE POLICY AND PROCEDURE GUIDE and ADDITIONAL WARRANTY EXCLUSIONS Resetting of safety thermostats, circuit breakers, over cleaning schedules, are customer responsibility.
  • Page 3 PARTS & SERVICE CUSTOMER SERVICE DATA INTRODUCTION Thank You for purchasing this Wells Bloomfield appliance. Proper installation, professional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long, economical service life.
  • Page 4 FEATURES & OPERATING CONTROLS HUMITROL RACK DRAWER INSERT PAN AIR VENT CONTROL HEATING INDICATOR TEMPERATURE CONTROL POWER CORD ADJUSTABLE ROLLER CATCH DRAWER GASKET DRAWER STOP DRAWER ROLLER DRAWER SLIDE DRAWER DRAWER SLIDE CATCH DRAWER HEATING ROLLERS ELEMENT...
  • Page 5: Agency Listing Information

    PRECAUTIONS AND GENERAL INFORMATION This appliance is intended for use in commercial establishments WARNING: only. ELECTRIC SHOCK HAZARD This appliance is intended to prepare food for human consumption. No other use is recommended or authorized by the manufacturer or its All servicing requiring agents.
  • Page 6 INSTALLATION NOTE: DO NOT discard UNPACKING & INSPECTION the carton or other packing Carefully remove the appliance from the carton. Remove all materials until you have protective plastic film, packing materials and accessories from the inspected the appliance for Appliance before connecting electrical power or otherwise performing hidden damage and tested it any installation procedure.
  • Page 7 INSTALLATION (continued) ELECTRICAL WARNING: SHOCK HAZARD Refer to electrical specifications on page 1. Circuit must meet or exceed the amperage and wattage requirements listed. All servicing requiring 120 Volt units require a properly grounded NEMA 5-15R receptacle: access to non-insulated electrical components must be performed by a factory authorized technician.
  • Page 8 2. Moist heat with pans: NOTE: a. This Wells warmer is designed to accommodate any The chart below is intended combination of standard-size, steam table pans. as a guide ONLY. Your own b.
  • Page 9 OPERATION (continued) OPERATION CAUTION: HOT SURFACE 1. Determine the type of food to be warmed. 2. Refer to the chart on page 6 to determine the type of heat required. Exposed surfaces can be hot 3. Set the air vent control for the type of heat, and rotate the to the touch and may cause thermostat knob to the temperature setting desired.
  • Page 10 CLEANING INSTRUCTIONS CAUTION: PRECAUTIONS: Turn control knob to OFF. Allow drawers to cool before proceeding. SHOCK HAZARD Remove drawer pans and Humitrol racks. Disconnect appliance from FREQUENCY: Minimum -Daily electric power before cleaning. TOOLS: Warm water and mild detergent CAUTION: Clean cloth or sponge HOT SURFACE Exposed surfaces can be hot...
  • Page 11 Warmer unplugged receptacle No lights or heat Circuit breaker off or tripped Reset circuit breaker (all drawers) Contact an Authorized Wells Internal damage Service Agency for repairs. Temperature control not set Set for desired temperature. No heat (one drawer) Contact an Authorized Wells Internal damage Service Agency for repairs.
  • Page 12 MAINTENANCE INSTRUCTIONS (continued) ADJUSTMENTS AND LUBRICATION CAUTION: SHOCK HAZARD PRECAUTIONS: Turn control knob to OFF. Unplug warmer Allow drawers to cool before proceeding. Disconnect appliance from Remove drawer pans and Humitrol racks electric power before cleaning. FREQUENCY: Minimum - monthly. Every 2 weeks recommended. CAUTION: TOOLS: Screwdrivers, Phillips (+) and flat blade (-).
  • Page 13 CAVITY and CABINET INTERIOR—COMMON TO ALL HD VERSIONS 50471 (includes strike and catch) 18-302 (typ.) 55677 55683 50482 (240V) 50519 (120V) 65923 (set - includes left and right) 64475 OPTIONAL THERMOMETER 55687 63271 50483 (pk 6) (pk 10) 58936 51801(UPPER) 53565 (LOWER) 50372 WELLS...
  • Page 14 O P E WS-51796 WS-69244 DD-61262 WS-69248 CAVITY and CABINET INTERIOR—COMMON TO ALL “NARROW” VERSIONS 2C-30471 (includes strike and catch) 2N-49255UL (120V) C8-35683 2N-49475UL(240V) 2C-35455 C8-35677 2T-44475 OPTIONAL 2A-45405 THERMOMETER C8-35988 2J-35687 2C-43271 2P-30483 WS-58936 C8-49257 2R-30372 WELLS WELLS IL2093...
  • Page 15 M041 p/n 2M-303335 Owners M Free-Standing Drawer Warmer...
  • Page 16: Customer Service Data

    5C-22228 service, or to order factory authorized replacement parts, LEG KIT, 4" PLASTIC (SET OF 4) 5D-20314 contact your Wells authorized LEG KIT, 4" METAL (SET OF 4) 5D-20563 service agency, or call: LEG KIT, 6" METAL (SET OF 4)
  • Page 17 WELLS BLOOMFIELD, LLC 10 Sunnen Dr., St. Louis, MO 63143 telephone: 888-356-5362 fax: 314-781-2714 www.wells-mfg.com...