Porter-Cable CPLC7060V Instruction Manual page 17

Single stage oillube compressor
Hide thumbs Also See for CPLC7060V:
Table of Contents

Advertisement

Motor
This motor has a manual thermal overload protector. If the motor overheats for any
reason, the overload protector will shut off the motor. The motor must be allowed
to cool down before restarting. To restart:
1.
Place the On/Auto/Off lever in the Off position.
2.
Allow the motor to cool.
3.
Depress the red reset button on the motor.
4.
Place the On/Auto/Off lever in the On/Auto postion
to restart the motor.
IMPORTANT: If the overload protector shuts the motor
off frequently, check for a possible voltage problem.
Low voltage can also be suspected when:
1.
The motor does not get up to full power or speed.
2.
Fuses blow out when starting the motor; lights dim
and remain dim when motor is started and is running.
To Replace Belt
Never operate the unit with the belt guard removed. The belt guard should
be removed only when the compresor is unplugged.
1.
Unplug compressor.
2.
Remove the front of the belt guard by
disengaging the snaps. Insert a flat
bladed screwdriver at each snap loca-
tion and pry the beltguard apart.
3.
Loosen the wing nut on hold down
plate and tilt motor to allow for easy
removal or installation of the belt.
4.
Remove belt.
5.
Replace belt. NOTE: The belt must be
centered over the grooves on the fly-
wheel and motor pulley.
6.
Turn the wing nut on the hold down
plate until it makes contact with the
washer, plus one additional turn.
7.
Replace the belt guard.
Serious injury or damage may occur if parts of the
body or loose items get caught in moving parts.
17 - ENG
Belt Guard
Wing Nut
D23269