figure 17
INSTALLING FLAShING AND STORM
COLLAR
Remove the nails from the shingles above and to the sides
of the chimney. Place the flashing over the chimney pipe and
slide underneath the sides and upper edge of the shingles.
Ensure that the chimney pipe is properly centered within the
flashing, giving a 3/4" margin all around. Fasten to the roof on
the top and sides. dO NOT NAIl through the lower portion
of the flashing. Make weather-tight by sealing with caulking.
Where possible, cover the sides and top edges of the flashing
with roofing material. Apply waterproof caulking, provided with
the flashing, around the chimney, 1" above the top of the flash-
ing and push the storm collar down into the caulking. Insert
a rain cap onto the top of the last chimney section.
CONNECTION TO A MASONRY
ChIMNEY
Napoleon Models NZ-26 &
NZ-26WI may be connected
to either a lined or unlined
masonry chimney.
IF THE CHIMNEy IS
LINEd
, the flues must be
made of vitrified clay and be
in sizes of 8" square, 8" x 12",
or 8" round with a minimum
height of 11 feet above the
fireplace. Eight inch round
flues are recommended.
Installation must conform to
both national and local code
requirements.
figure 19
IF THE
CHIMNEy IS
UNLINEd:
A stainless steel
liner listed to either
S t a n d a r d u L C -
S 6 4 0 M , u L C -
S69 in Canada
o r u L - 1 7 7 7 i n
the uSA: Liners
for New Masonry
Chimneys, may be
used to connect
the fireplace to the
chimney. The liner
must be continuous
from the fireplace
t o t h e c h i m n e y
cap and be installed only per manufacturers instructions.
Figure 19. In both cases, the chimney structure must be
supported by angle iron anchored into the masonry walls.
Figures 19 & 20. The allowable masonry used in chimney
construction is -1/2"
encasing the flue. Ensure there are no leaks.
In no case is the masonry enclosure to be supported by the
NZ-26 fireplace. Allow a 1" (one inch) air cavity for expan-
figure 18
sion.
ANCHOR PLATE
HI-TEMP GASkET
FLUE TILE SUPPORT FOR A MASONRy FIREPLACE
For a masonry fireplace use a flue tile support. For a pre-
fabricated chimney use an anchor plate.
figure 20
brick, solidly mortared and fully
FIREPLACE TOP
HI-TEMP GASkET
FIREPLACE TOP
W415-0585 / B / 11.28.06
11
figure 21
figure 22

Hide quick links: