INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER.
THIS FIREPLACE HAS BEEN TESTED AND LISTED BY INTERTEK TESTING SERVICES TO STANDARDS: CAN/ULC S610, UL 127, FOR ZERO CLEARANCE FIREPLACES, AND TO ULC
S639 FOR STEEL LINER ASSEMBLIES FOR SOLID FUEL BURNING MASONRY FIREPLACES. CERTIFIED UNDER USA ENVIRONMENTAL PROTECTION AGENCY (E.P .A.) JULY 1990 AND
THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE EMISSION STANDARDS
NZ-26
NZ-26WI
R-2000
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 4Y8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030
(705)721-1212 • fax(705)722-6031 • www.napoleonfireplaces.com • ask@napoleon.on.ca
INSTALLATION
OPERATING INSTRUCTIONS
If the information in these instructions is not followed
exactly, a fire or explosion may result causing property
damage, personal injury or death.
SOLID FUEL BURNING - ZERO CLEARANCE
Installation and operation instructions for Hi-Tech
AND
listed fireplace
W415-0585 / B / 11.28.06
1

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon NZ-26

  • Page 1 THE OREGON DEPARTMENT OF ENVIRONMENTAL QUALITY (D.E.Q.) PARTICULATE EMISSION STANDARDS If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. NZ-26 SOLID FUEL BURNING - ZERO CLEARANCE Installation and operation instructions for Hi-Tech listed fireplace...
  • Page 2 WARNINGS & SAFETY PRECAUTIONS W415-0585 / B / 11.28.06...
  • Page 3: Table Of Contents

    Fuel Loading and Burn Cycle Ash Removal Procedures Five Options MAINTENANCE INSTALLATION / FRAMING Gasket / Baffle Replacement NZ-26WI Location & Clearance NZ-26 Door Glass Replacement NZ-26WI Framing NZ-26WI Door Glass Replacement NZ-26 Location & Clearance Creosote Formation And Removal NZ-26 Framing Run-Away or Chimney Fire...
  • Page 4 napoleon products are manufactured under the strict Standard of the World Recognized ISo 9001 : 2000 Quality assurance Certificate. napoleon products are designed with superior components and materials, assembled by trained craftsmen who take great pride in their work. The complete fireplace is thoroughly inspected by a qualified technician before packaging to ensure that you, the customer, receives the quality product that you expect from napoleon.
  • Page 5: Introduction

    The combustion chamber is lined with high-temperature firebrick down cycles are normal and to be expected. on all sides, and across the bottom to maintain a high tempera- Mobile home installation (NZ-26 ONLY) requires that ture in the combustion chamber so that gases mixing with the the fireplace be secured to the floor. It is recommended that preheated air from the secondary air tubes are easily ignited in all cases, the fireplace be secured to the floor. Use the...
  • Page 6: Hi-Efficiency Heating

    No more than two hot air gravity vents can be installed to fireplace. Individual vent runs are not to exceed 10 feet. NOTE: MASONRY REMOTE VENTING OPTIONS COME OFF THE SIDE INSTEAD OF THE TOP. All hot air gravity vents must be insulated. NZ-26: CENTRAL HEATING & CENTRAL HEATING DUCTING GRAVITY VENT OPTION...
  • Page 7 figure 8b: framing requirements Nz-26WI LOCATION & CLEARANCES Do not build shelves or cupboards into the area above the fireplace. While the fireplace can be installed directly on the floor, a non-combustible hearth extension is required in front of the fireplace, that must not be built higher than the bottom of the fireplace to avoid air flow blockage. It may therefore be advis- able to build the fireplace on a raised platform. The minimum...
  • Page 8: Installation / Framing

    INSTALLATION / FRAMING figure 7b: framing requirements Nz-26 LOCATION & CLEARANCES Do not build shelves or cupboards into the area above the fireplace. While the fireplace can be installed directly on the floor, a non-combustible hearth extension is required in front of the fireplace, that must not be built higher than the bottom of the fireplace to avoid air flow blockage. It may therefore be advis-...
  • Page 9: Outside Combustion Air

    The chimney should not be built with an offset angle in excess of 45° in Canada and 0° in uSA. The NZ-26 & NZ-26WI were tested to CAN/uLC S610 and uL 127 Factory Built Fireplace Standards. These Fireplaces have met the test criteria for Zero Clearance Installation to Combustible Surfaces and Certified to burn Firewood only.
  • Page 10 figure 11 - straight up figure 12 - 2 elbows figure 13 - 4 elbows Single off-set with two 15°, 0° or 45° Double off-set with four 15°, 0° or No Off-Set. Minimum overall chimney elbows. Minimum overall chimney 45° elbows. Minimum overall chimney height is 11 feet.
  • Page 11 HI-TEMP GASkET FIREPLACE TOP figure 21 CONNECTION TO A MASONRY FLUE TILE SUPPORT FOR A MASONRy FIREPLACE ChIMNEY Napoleon Models NZ-26 & NZ-26WI may be connected to either a lined or unlined HI-TEMP GASkET masonry chimney. IF THE CHIMNEy IS...
  • Page 12 1. Insert the door rod through the round hole of the latch ensuring the flat edge of the “D” shaped hole points towards Nz-26 ATTAChING ThE hANDLE the hinges. Attach the handle as shown so that 2. Slide the end of the door rod through the bushing at the when the door is closed, the handle top of the door as shown.
  • Page 13 If you need to remove the bricks (to lighten the fireplace for ease of installation, replacement, etc), follow this se- quence: For Firebrick Removal: Remove the ashwell grate. This allows the four bottom bricks to be removed first. top flAme spreAder Slide out the baffle support bracket from above the front tube.
  • Page 14 OPTIONAL BLOWER INSTALLATION INsTAllATION TO Be DONe By A quAlIFIeD INsTAller and must be electrically connected and grounded in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the united States.
  • Page 15 FEATURES CONTROLLING COMBUSTION AIR AChIEVING PROPER DRAFT If the outside combustion air kit is not used, air may still be Draft is the force which moves air from the fireplace up through drawn directly into the fireplace through the lower louvres. the chimney. The amount of draft in your chimney depends on Outside and inside air may be combined by pulling the outside the length of the chimney, local geography, nearby obstruc- air lever out as far as possible, and turning the lever 90°...
  • Page 16 OPERATING INSTRUCTIONS Remove all source of gasoline or other flammable Can't get heat out of the stove? One of two things may have happened. The fireplace door may have been closed vapours and liquids in the vicinity of this or other prematurely and the fireplace itself has not reached optimum appliances prior to lighting. Ensure that the top temperature.
  • Page 17 At this time also check that the door gasket is not worn 2. Be careful not to overfire the unit by leaving the door open or loose. Replace with 1/2" fibreglass rope if necessary. too long after the initial start-up. Nz-26 DOOR GLASS REPLACEMENT 3. Always operate the fireplace with the ash well in a closed position. To remove the door, open and lift out; remove the screws and 4.
  • Page 18 WEBBED BLACk DOOR & w handle gasket H4G WEBBED GOLD PLATED DOOR & w handle gasket Nz-26 REPLACEMENT PARTS NZLPB uPPER & LOWER LOuvRE ASSEMBLY- polished brass NZLk uPPER & LOWER LOuvRE ASSEMBLY - black PART NO. DESCRIPTION NZLG uPPER & LOWER LOuvRE ASSEMBLY -...
  • Page 19 W415-0585 / B / 11.28.06...
  • Page 20 TROUBLE ShOOTING GUIDE Expansion / contraction noises during heating up and cooling BUILd yOUR FIRE ON THE FLOOR OF THE FIRE- down cycles are normal and to be expected. When first light- BOx ANd BEHINd THE LOG RETAINER ONLy. ing a fire, if the smoke is not quickly drawn into the chimney, there may be a downdraft or cold air in the chimney. Roll up do not block or restrict the hot air outlets or air some newspaper, light it and place it near the fireplace flue inlets.